C01. Carriage Purpose Ć Calibrate the temperature from which the printhead has to be warmed. THIS CALIBRATION MUST BE DONE WITH THE PRINTHEADS INSTALLED. If C0100 OK" Ć Calibration done. If C01xx Fail" Ć Perform Electronics test. C02. Refill Purpose Ć To ensure the correct position of the carriage assembly in respect to the refill assembly. When the Carriage Assembly, Refill Assembly or the Electronics Assembly is ordered, a Refill Calibration Tool, a special Carriage height gauge and an Instructions flyer will be included. You must follow the instructions in the flyer in order to correctly calibrate the Refill Assembly and to make sure that the Carriage is at the correct height. C03. Line Sensor Purpose Ć Calibrate the intensity of the line sensor in the carriage PCA. Load white media before performing this calibration. WINDOW MUST CLOSED BEFORE YOU PERFORM THIS CALIBRATION. REPLACE THE LENS COVER BEFORE YOU PERFORM THIS CALIBRATION IN ORDER TO PREVENT ANY AEROSOL PROBLEMS. If C0300 Done" Ć Calibration done. C04. Service Station THIS CALIBRATION IS NO LONGER VALID AND SHOULD NEVER BE PERFORMED. C05. Printheads Alignment Purpose Ć To test and if necessary correct the misalignment between the printheads. WINDOW MUST CLOSED BEFORE YOU PERFORM THIS CALIBRATION. If C0500 Done" Ć Calibration done. If C0501 Fail" Ć If the calibration pattern is bad, try recovering printheads using the frontĆpanel menu and try the calibration again. If the calibration pattern is bad again, then replace the complete Ink Delivery System of the color that is bad. Perform Electronics Test. Perform Line Sensor Test. HP DesignJet 2500CP and 2000CP Printers Quick Reference Service Manual 13

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18

Quick Reference Service Manual
13
HP DesignJet 2500CP and 2000CP Printers
C01. Carriage
Purpose Ć Calibrate the temperature from which the printhead has to be warmed.
THIS CALIBRATION MUST BE DONE WITH THE PRINTHEADS INSTALLED.
If ±
C0100 OK
" Ć Calibration done.
If ±
C01xx Fail
" Ć Perform Electronics test.
C02. Refill
Purpose Ć To ensure the correct position of the carriage assembly in respect to the refill assembly.
When the Carriage Assembly, Refill Assembly or the Electronics Assembly is ordered, a Refill
Calibration Tool, a special Carriage height gauge and an Instructions flyer will be included.
You must follow the instructions in the flyer in order to correctly calibrate the Refill
Assembly and to make sure that the Carriage is at the correct height.
C03. Line Sensor
Purpose Ć Calibrate the intensity of the line sensor in the carriage PCA.
Load white media before performing this calibration.
WINDOW MUST CLOSED BEFORE YOU PERFORM THIS CALIBRATION.
REPLACE THE LENS COVER BEFORE YOU PERFORM THIS
CALIBRATION IN ORDER TO PREVENT ANY AEROSOL PROBLEMS.
If ±
C0300 Done
" Ć Calibration done.
C04. Service Station
THIS CALIBRATION IS NO LONGER VALID AND SHOULD NEVER BE
PERFORMED.
C05. Printheads Alignment
Purpose Ć To test and if necessary correct the misalignment between the printheads.
WINDOW MUST CLOSED BEFORE YOU PERFORM THIS CALIBRATION.
If ±
C0500 Done
" Ć Calibration done.
If ±
C0501 Fail
" Ć If the calibration pattern is bad, try recovering printheads using the
frontĆpanel menu and try the calibration again. If the calibration pattern is bad again, then
replace the complete Ink Delivery System of the color that is bad. Perform Electronics Test.
Perform Line Sensor Test.