HP Integrity Superdome 2 16-socket HP Superdome 2 Health Management Stack Whit
HP Integrity Superdome 2 16-socket Manual
View all HP Integrity Superdome 2 16-socket manuals
Add to My Manuals
Save this manual to your list of manuals |
HP Integrity Superdome 2 16-socket manual content summary:
- HP Integrity Superdome 2 16-socket | HP Superdome 2 Health Management Stack Whit - Page 1
Repository...5 Web Services for Management (WS-MAN 5 User Interfaces and Management Notifications 6 CAE Event Viewer ...6 Onboard Administrator (OA) Web GUI 8 Health Repository Viewer ...9 ALERT MAIL...11 SNMP Trap ...12 HP Insight Remote Support Advanced (RSA) Support for the HP Superdome 2 OA - HP Integrity Superdome 2 16-socket | HP Superdome 2 Health Management Stack Whit - Page 2
to self-heal the problem and reports any problems that require the system to be serviced. It can report directly to customers; and for systems under warranty, to HP Customer Support via HP Insight Remote Support (Insight RS). HP Superdome 2 Analysis Engine Overview The HP Superdome 2 Analysis Engine - HP Integrity Superdome 2 16-socket | HP Superdome 2 Health Management Stack Whit - Page 3
and to the problem-cause-action in the WS-MAN alerts sent to Remote Support Tools and HP-SIM. Because this is all built into the sx3000 chipset and OA firmware, HP Superdome 2 does not built-in fault management: 1. Error Logging Service (ELS) 2. Core Analysis Engine (CAE) 3. Health Repository 3 - HP Integrity Superdome 2 16-socket | HP Superdome 2 Health Management Stack Whit - Page 4
Figure 1: HP Superdome 2 (SD2) Analysis Engine Error Logging Services Error Logging Services (ELS) is responsible analysis. The Actions initiated by CAE are: − Indictment -> Identifies a FRU as requiring service − Suspicion -> Identifies a FRU that may be involved in a fault event − Deconfigure - HP Integrity Superdome 2 16-socket | HP Superdome 2 Health Management Stack Whit - Page 5
2 platform. The main component of WS-MAN on HP Superdome 2 is the WS-MAN daemon running on the HP Superdome 2 OA. WS-Man daemon reads requests for data transfer, subscriptions etc and acts on those requests. The WS-MAN daemon supports the Subscribe and Unsubscribe WS-MAN commands. Subscribe - HP Integrity Superdome 2 16-socket | HP Superdome 2 Health Management Stack Whit - Page 6
receiving an indication from CAE, the WS-Man daemon running on HP Superdome 2 OA will iterate over its list of event subscribers. For information directly from WS-Man daemon. Network applications, such as WEBES and HP SIM create subscriptions to WS-Man daemon which stores the subscription in the - HP Integrity Superdome 2 16-socket | HP Superdome 2 Health Management Stack Whit - Page 7
:54 2011 : 510081920110721004954 Managed Entity : OA Name System Type System Serial No. OA IP Address : stern-oa : 59 : USE22334422 : 16.119.96.121 Affected Domain : Enclosure Name RackName RackUID Impacted Domain Complex Name Partition ID : SGH747C4AH : Rack1 : 021Z34AB7890 : Complex : Complex1 - HP Integrity Superdome 2 16-socket | HP Superdome 2 Health Management Stack Whit - Page 8
Log Data : Error Log Bundle : 45 Onboard Administrator (OA) Web GUI The HP Superdome 2 OA Web GUI is accessed by pointing a browser at the OA's IP the window is the system status pane, which lists the number of problems present in the system, categorized by severity. Any FRUs with abnormal health - HP Integrity Superdome 2 16-socket | HP Superdome 2 Health Management Stack Whit - Page 9
in the system. Acquitting a FRU refers to clearing the indictment and deconfiguration statuses and would typically be done when the part is serviced. Commonly used HRUI COMMANDS: SHOW HR: Launches the Health Repository viewer. SHOW INDICT: Lists all currently indicted FRUs for the complex SHOW - HP Integrity Superdome 2 16-socket | HP Superdome 2 Health Management Stack Whit - Page 10
in HR - Thu Jul 21 01:04:40 2011 FRU Type: CPU Socket Location: 0x0100FF01FF00FF11 enclosure1/blade1/cpusocket0 Timestamp: Thu Jul 21 00:49:52 : MYJ01304MX Part Num: AH339-2018A Spare Part Num: AH339-2018A Manufacturer ID: HP Product Name: TUK_E0_1724 Max Core Freq: 1866 Mhz L3 Cache Size: 24 MB - HP Integrity Superdome 2 16-socket | HP Superdome 2 Health Management Stack Whit - Page 11
DNS domain where the Onboard Administrator is located (e.g. usa.hp.com). 4. SET ALERTMAIL SMTPSERVER : Sets the SMTP server. This is the mail server where the Onboard Administrator will deliver its email based events (e.g. 16.236.32.51). 5. TEST ALERTMAIL: Sends a test AlertMail message - HP Integrity Superdome 2 16-socket | HP Superdome 2 Health Management Stack Whit - Page 12
: https://16.118.232.170/ - PLEASE DO NOT REPLY TO THIS EMAIL - SNMP Trap The Onboard Administrator supports SNMP Version Support, WS-Man is mandatory and SNMP is not used. By default SNMP is not enabled for HP Superdome 2. Customers can enable SNMP Trap alerting when they want to integrate Superdome - HP Integrity Superdome 2 16-socket | HP Superdome 2 Health Management Stack Whit - Page 13
Configure SNMP from the OA CLI: 1. ENABLE SNMP: Enables SNMP Trap support for the Onboard Administrator. 2. ADD SNMP TRAPRECEIVER [ "" ]: Adds a new trap receiver address to the SNMP configuration. By default the community name/ - HP Integrity Superdome 2 16-socket | HP Superdome 2 Health Management Stack Whit - Page 14
Traps without needing additional information if the Traps use the default public community string. HP SIM receiving a Trap will trigger a discovery of the originating system so that HP SIM can add it to the servers it monitors if it was not configured to discover that system beforehand. SNMP Traps - HP Integrity Superdome 2 16-socket | HP Superdome 2 Health Management Stack Whit - Page 15
Received by HP SIM HP Insight Remote Support Advanced (RSA) Support for the HP Superdome 2 OA Architectural Overview The HP Insight Remote Support Software is a portfolio of infrastructure remote support tools that automatically provides secure remote support for HP Servers and Storage. HP Insight - HP Integrity Superdome 2 16-socket | HP Superdome 2 Health Management Stack Whit - Page 16
needing to participate in the fault recovery process or support center engineers needing to dial into the SD2 and manually analyze these events. For each service incident WEBES logs to the support center, WEBES also sends an event to HP-SIM providing the customer with detailed information on the - HP Integrity Superdome 2 16-socket | HP Superdome 2 Health Management Stack Whit - Page 17
Figure 5: Insight Remote Support WEBES support for the HP Superdome 2 WEBES monitors both the SD2 OA and the HP-UX partitions for hardware events that may require service action. WEBES subscribes to the SD2 OA WS-Man interface and to the HP-UX WBEM Providers using the system identification, IP - HP Integrity Superdome 2 16-socket | HP Superdome 2 Health Management Stack Whit - Page 18
. Detailed information on configuring HP Insight Remote Support Advanced to monitor the HP Superdome 2 is provided in chapter 10: Integrity Superdome 2 Server Configuration of the HP Insight Remote Support Managed Systems Configuration Guide accessible from: www.hp.com/go/insightremoteadvanced-docs - HP Integrity Superdome 2 16-socket | HP Superdome 2 Health Management Stack Whit - Page 19
WEBES Web UI Output 19 - HP Integrity Superdome 2 16-socket | HP Superdome 2 Health Management Stack Whit - Page 20
Sample WSMAN indication in HP SIM 20 - HP Integrity Superdome 2 16-socket | HP Superdome 2 Health Management Stack Whit - Page 21
information • HP Insight Remote Support Managed Systems Configuration Guide : www.hp.com/go/insightremoteadvanced-docs • HP Insight Remote Support Advanced Information library: www.hp.com/go/insightremoteadvanced-docs • For information on specific Port Requirements: http://bizsupport2.austin.hp.com
HP Superdome 2 Health Management Stack
Firmware based solution for complete fault management coverage
Technical white paper
Table of contents
Executive Summary
.........................................................................................................................
2
The Legacy HP Superdome Manageability Solution
..........................................................................
2
The HP Superdome 2 Manageability Solution
.................................................................................
2
HP Superdome 2 Analysis Engine
.....................................................................................................
2
Overview
...................................................................................................................................
2
Analysis Engine Operation
...........................................................................................................
3
Error Logging Services
.................................................................................................................
4
Core Analysis Engine
..................................................................................................................
4
Health Repository
........................................................................................................................
5
Web Services for Management (WS-MAN)
....................................................................................
5
User Interfaces and Management Notifications
...................................................................................
6
CAE Event Viewer
.......................................................................................................................
6
Onboard Administrator (OA) Web GUI
.........................................................................................
8
Health Repository Viewer
.............................................................................................................
9
ALERT MAIL
..............................................................................................................................
11
SNMP Trap
..............................................................................................................................
12
HP Insight Remote Support Advanced (RSA) Support for the HP Superdome 2 OA
.................................
15
Architectural Overview
..............................................................................................................
15
WEBES support for the HP Superdome 2
......................................................................................
17
Enabling Insight Remote Support Advanced support for HP Superdome 2 using WEBES and HP SIM
....
18
For more information
....................................................................................................................
21