HP Integrity Superdome 2 8/16 HP Superdome 2 Partitioning Administrator Guide - Page 18

Example 2-1 Unique IDs for an nPartition and Complex

Page 18 highlights

The interfaces include the _CS_PARTITION_IDENT and _CS_MACHINE_IDENT parameters: • For a nPartition-specific or a virtual partition-specific unique ID use this command: /usr/bin/getconf _CS_PARTITION_IDENT The unique partition identifier value for a virtual partition environment has virtual partition-specific data added that does not appear for an equivalent non-vPars environment. See the examples that follow. • For a complex-specific unique ID use this command: /usr/bin/getconf _CS_MACHINE_IDENT Example 2-1 Unique IDs for an nPartition and Complex The following examples show nPartition-unique and complex-unique IDs returned by the getconf command, as well as the local nPartition number and machine serial number. # parstatus -w The local partition number is 1. # /usr/bin/getconf _CS_PARTITION_IDENT Z3e02955673f9f7c9_P1 # /usr/bin/getconf _CS_MACHINE_IDENT Z3e02955673f9f7c9 # /usr/bin/getconf _CS_MACHINE_SERIAL USR2024FP1 # Example 2-2 Unique IDs for Virtual Partitions (vPars) The following example shows the virtual partition-unique ID returned by the getconf command, as well as the local nPartition number and the current virtual partition name. # parstatus -w The local partition number is 0. # vparstatus -w The current virtual partition is Shad. # getconf _CS_PARTITION_IDENT Z3e0ec8e078cd3c7b_P0_V00 # For details on virtual partitions, see Chapter 9 "Installing or Removing the vPars". 18 Partitioning in HP Superdome 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106

The interfaces include the
_CS_PARTITION_IDENT
and
_CS_MACHINE_IDENT
parameters:
For a nPartition-specific or a virtual partition-specific unique ID use this command:
/usr/bin/getconf _CS_PARTITION_IDENT
The unique partition identifier value for a virtual partition environment has virtual
partition-specific data added that does not appear for an equivalent non-vPars environment.
See the examples that follow.
For a complex-specific unique ID use this command:
/usr/bin/getconf _CS_MACHINE_IDENT
Example 2-1 Unique IDs for an nPartition and Complex
The following examples show nPartition-unique and complex-unique IDs returned by the
getconf
command, as well as the local nPartition number and machine serial number.
#
parstatus -w
The local partition number is 1.
#
/usr/bin/getconf _CS_PARTITION_IDENT
Z3e02955673f9f7c9_P1
#
/usr/bin/getconf _CS_MACHINE_IDENT
Z3e02955673f9f7c9
#
/usr/bin/getconf _CS_MACHINE_SERIAL
USR2024FP1
#
Example 2-2 Unique IDs for Virtual Partitions (vPars)
The following example shows the virtual partition-unique ID returned by the
getconf
command,
as well as the local nPartition number and the current virtual partition name.
#
parstatus -w
The local partition number is 0.
#
vparstatus -w
The current virtual partition is Shad.
#
getconf _CS_PARTITION_IDENT
Z3e0ec8e078cd3c7b_P0_V00
#
For details on virtual partitions, see
Chapter 9 “Installing or Removing the vPars”
.
18
Partitioning in HP Superdome 2