Replacing Components Replacing Power Supplies Replacing Power Supplies If your ProCurve 5400zl Switch is configured with redundant power supplies, you will not suffer any loss of traffic or performance if a power supply fails. Replace the failed component as soon as possible. One of the Internal Power LEDs on the management module will blink simultaneously with the switch Fault LED indicating which power supply failed. Although these procedures show the 6-slot chassis, the procedures are the same for the 12-slot chassis. To remove an AC power supply: 1. Ensure the AC power supply is not plugged into an AC power source on the failed power supply. 2. Using either a flat-bladed or Torx T-10 screwdriver loosen the retaining screws and remove the failed power supply. Figure 4-1. Power Supply Removal 4-2 Replacing Components