HP StorageWorks 2/16V Brocade Fabric OS MIB Reference (53-1000241-01, November - Page 110
fcFxPortCapHoldTimeMin 1.3.6.1.3.42.2.1.5.1.1.15
View all HP StorageWorks 2/16V manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 110 highlights
3 fcFxPortCapIntermix 1.3.6.1.3.42.2.1.5.1.1.10 fcFxPortCapIntermix 1.3.6.1.3.42.2.1.5.1.1.10 Values A flag indicating whether the Fx_Port is capable of supporting the intermixing of Class 2 and Class 3 frames during a Class 1 connection. This flag is only valid if the port is capable of supporting Class 1 service. Possible values are: • yes (1) • no (2) fcFxPortCapStackedConnMode 1.3.6.1.3.42.2.1.5.1.1.11 A value indicating the mode of Stacked Connect request that the Fx_Port is capable of supporting. fcFxPortCapClass2SeqDeliv 1.3.6.1.3.42.2.1.5.1.1.12 Values A flag indicating whether the Fx_Port is capable of supporting Class 2 Sequential Delivery. Possible values are: • yes (1) • no (2) fcFxPortCapClass3SeqDeliv 1.3.6.1.3.42.2.1.5.1.1.13 Values A flag indicating whether the Fx_Port is capable of supporting Class 3 Sequential Delivery. Possible values are: • yes (1) • no (2) fcFxPortCapHoldTimeMax 1.3.6.1.3.42.2.1.5.1.1.14 The maximum holding time (in microseconds) that the Fx_Port is capable of supporting. fcFxPortCapHoldTimeMin 1.3.6.1.3.42.2.1.5.1.1.15 The minimum holding time (in microseconds) that the Fx_Port is capable of supporting. fcFxPortCapBaudRates 1.3.6.1.3.42.2.1.5.1.1.16 A value indicating the set of baud rates that the Fx_Port is capable of supporting. This variable has been deprecated and might be implemented for backward compatibility. 3-46 Fabric OS MIB Reference Publication Number: 53-1000241-01