HP StorageWorks 4000 Compaq RAID Array 4000 Overview - Page 13
components of up to 500 meters on 50-micron, multi-mode fiber optic cable with no
View all HP StorageWorks 4000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 13 highlights
Compaq RAID Array 4000 Overview 13 Figure 7 shows that the Storage Hub 7 contains seven serially connected ports. The Storage Hub 12, on the other hand, contains 12 serially connected ports. Internal signaling within the hubs is electrical. The internal hub connections and logic create an FC-AL. The bandwidth of the loop is shared by all ports on the loop. A single pair of ports on the loop communicates at any one time, while the other ports on the loop act as repeaters. Each port is fitted with a port bypass switch to maintain the continuity of the loop in the event a controller or device attached to that port malfunctions or is powered off. This port bypass capability improves fault tolerance. Figure 7. Compaq StorageWorks Fibre Channel Storage Hub 7 The shortwave laser technology used in the RA4000 supports transmission distances between components of up to 500 meters on 50-micron, multi-mode fiber optic cable with no electromagnetic interference. Consequently, the Fibre Channel Host Adapter can be located as much as 500 meters from the Fibre Channel Storage Hub, which in turn can be located as much as 500 meters from the RA4000s. GBIC-LW and single-mode fiber optic cables increase the point-to-point connection distance to 10 kilometers. Server GBIC-LW < 10 km GBIC-LW < 10 km Array Hub GBIC-SW < 500 m Figure 8. Possible storage configurations GBIC-SW < 500 m ECG0205699A