HP Vectra VT 6/xxx HP Vectra XU 6/xxx and VT 6/xxx PCs - Technical Reference M - Page 45

HP Vectra XU 6/xxx PC, HP Vectra VT, xxx PC

Page 45 highlights

as "4..7", which means "4 or 5 or 6 or 7", and the letter "x" is used to mean "any hexadecimal digit, 0..F"). Underneath each error code, there is a short summary of the error diagnosis. In order to find the suggested corrective action (SCA), it is necessary to read the five-character code that is given on the right of the error code. This SCA code can then be found in the list that is given in the next section of this chapter. Not all of these error codes can be generated by the HP Vectra XU 6/xxx PC or HP Vectra VT 6/xxx PC. However, the complete list is given here, to allow for possible future changes to the models within this product line. 0000 000E 0080..00DF 0110..011F, 0120 0130 0240 0241, 0280 0250 02C0, 02C1 02C2 02D0 0300..031F 0342, 0352, 0354 0343..0346, 0350, 0351, 0353, 0360 03E0..03E4, 03EC 03E5..03EB 0401 0505 0506 0507 0508 0509 050A 0510 0545 0546 An error of unspecified origin (no other error code was appropriate). A thermal error occurred during your last session. The ROM on an accessory board or the system board is corrupted. The real-time clock has failed. The system date and time has not been entered or has been lost or corrupted. The system configuration has been lost. The system configuration has been lost or corrupted. The Setup information does not match the hardware installed in the computer. The master configuration information (stored in EEPROM) has been lost or corrupted The Plug and Play Configuration Information has been corrupted. Your adapters may not function correctly. The PC Serial Number is not set. The keyboard/mouse controller on the system board has failed. The keyboard or its cable has failed. The keyboard or the keyboard controller on the system board has failed. The mouse or the mouse controller on the system board has failed. The mouse has failed. The system board has failed to switch to protected mode. The system board's serial port has failed. The built-in serial port's address is used by a serial port on an accessory board. The system board's serial port at address 3F8h has failed. The system board's serial port at address 2F8h has failed. The system board's serial port at address 3E8h has failed. The system board's serial port at address 2E8h has failed. The infra red port has failed. The system board's parallel port has failed. The built-in parallel port's address is used by a parallel port on an accessory board. SCA24 SCA33 SCA02 SCA01 SCA03 SCA04 SCA04 SCA05 SCA04 SCA30 SCA27 SCA06 SCA07 SCA06 SCA06 SCA08 SCA01 SCA09 SCA10 SCA09 SCA09 SCA09 SCA09 SCA26 SCA09 SCA10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51

as “4..7”, which means “4 or 5 or 6 or 7”, and the letter “x” is used to mean “any hexadecimal digit,
0..F”).
Underneath each error code, there is a short summary of the error diagnosis.
In order to find the suggested corrective action (SCA), it is necessary to read the five-character
code that is given on the right of the error code. This SCA code can then be found in the list that is
given in the next section of this chapter.
Not all of these error codes can be generated by the
HP Vectra XU 6/xxx PC
or
HP Vectra VT
6/xxx PC
. However, the complete list is given here, to allow for possible future changes to the
models within this product line.
0000
An error of unspecified origin (no other error code was
appropriate).
SCA24
000E
A thermal error occurred during your last session.
SCA33
0080..00DF
The ROM on an accessory board or the system board is
corrupted.
SCA02
0110..011F, 0120
The real-time clock has failed.
SCA01
0130
The system date and time has not been entered or has been lost
or corrupted.
SCA03
0240
The system configuration has been lost.
SCA04
0241, 0280
The system configuration has been lost or corrupted.
SCA04
0250
The
Setup
information does not match the hardware installed in
the computer.
SCA05
02C0, 02C1
The master configuration information (stored in EEPROM) has
been lost or corrupted
SCA04
02C2
The Plug and Play Configuration Information has been corrupted.
Your adapters may not function correctly.
SCA30
02D0
The PC Serial Number is not set.
SCA27
0300..031F
The keyboard/mouse controller on the system board has failed.
SCA06
0342, 0352, 0354
The keyboard or its cable has failed.
SCA07
0343..0346, 0350,
0351, 0353, 0360
The keyboard or the keyboard controller on the system board has
failed.
SCA06
03E0..03E4, 03EC
The mouse or the mouse controller on the system board has
failed.
SCA06
03E5..03EB
The mouse has failed.
SCA08
0401
The system board has failed to switch to protected mode.
SCA01
0505
The system board's serial port has failed.
SCA09
0506
The built-in serial port's address is used by a serial port on an
accessory board.
SCA10
0507
The system board's serial port at address 3F8h has failed.
SCA09
0508
The system board's serial port at address 2F8h has failed.
SCA09
0509
The system board's serial port at address 3E8h has failed.
SCA09
050A
The system board's serial port at address 2E8h has failed.
SCA09
0510
The infra red port has failed.
SCA26
0545
The system board's parallel port has failed.
SCA09
0546
The built-in parallel port's address is used by a parallel port on an
accessory board.
SCA10