HP Xw25p ProLiant BL25p Server Blade Maintenance and Service Guide - Page 15
HP Xw25p - ProLiant - Blade Workstation Manual
View all HP Xw25p manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 15 highlights
3. Open the processor cage latch. 4. Open the processor cage. 5. Remove the heatsink. 6. Open the processor locking lever. 7. Remove the processor. CAUTION: The heatsink is not reusable and must be discarded if removed from the processor after application. CAUTION: Always install a processor or a processor blank and 1P enabler board in processor socket 2. If processor socket 2 is empty, the server blade will not boot. To install the component: 1. Install the processor. CAUTION: Be sure that the processor socket locking lever is open before installing the processor into the socket. CAUTION: The processor is designed to fit one way into the socket. Use the alignment guides on the processor and socket to properly align the processor with the socket. Refer to the server blade hood label for specific instructions. 2. Close the processor locking lever. CAUTION: Be sure that the processor socket locking lever is closed after the processor is installed. The lever should close without resistance. Forcing the lever closed can damage the processor and socket, requiring system board replacement. Removal and replacement procedures 15