HP Xw25p ProLiant BL25p Server Blade Maintenance and Service Guide - Page 39

Specifications, Environmental specifications, Server specifications

Page 39 highlights

Specifications In this section Environmental specifications ...39 Server specifications ...39 Environmental specifications Specification Temperature range* Operating Shipping Storage Maximum wet bulb temperature Relative humidity (noncondensing)** Operating Shipping Storage Value 10°C to 35°C (50°F to 95°F) -40°C to 60°C (-40°F to 140°F) -20°C to 60°C (-4 to 140°C) 30°C (86°F) 10% to 90% 10% to 90% 10% to 95% * All temperature ratings shown are for sea level. An altitude derating of 1°C per 304.8 m (1.8°F per 1,000 ft) to 3048 m (10,000 ft) is applicable. No direct sunlight allowed. Upper operating limit is 3,048m (10,000 ft) or 70 Kpa/10.1 psia. Upper non-operating limit is 9,144 m (30,000 ft) or 30.3 KPa/4.4 psia. ** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for storage corresponds to a pressure minimum of 70 KPa. Server specifications Specification Height Depth Width Weight (maximum) Value 4.29 cm (1.69 in) 71.1 cm (28.00 in) 26.14 cm (10.29 in) 9.43 kg (20.8 lb) Specifications 39

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43

Specifications 39
Specifications
In this section
Environmental specifications
....................................................................................................................
39
Server specifications
...............................................................................................................................
39
Environmental specifications
Specification
Value
Temperature range*
Operating
10
°
C
to 35
°
C (50
°
F to 95
°
F)
Shipping
-40
°
C
to 60
°
C (-40
°
F to 140
°
F)
Storage
-20°C to 60°C (-4 to 140°C)
Maximum wet bulb temperature
30
°
C (86
°
F)
Relative humidity
(noncondensing)**
Operating
10% to 90%
Shipping
10% to 90%
Storage
10% to 95%
* All temperature ratings shown are for sea level. An altitude derating of 1°C per 304.8 m (1.8°F per 1,000 ft) to
3048 m (10,000 ft) is applicable. No direct sunlight allowed. Upper operating limit is 3,048m (10,000 ft) or 70
Kpa/10.1 psia. Upper non-operating limit is 9,144 m (30,000 ft) or 30.3 KPa/4.4 psia.
** Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 KPa.
Server specifications
Specification
Value
Height
4.29 cm (1.69 in)
Depth
71.1 cm (28.00 in)
Width
26.14 cm (10.29 in)
Weight (maximum)