HP Xw25p ProLiant BL25p Server Blade Maintenance and Service Guide - Page 38
Activity, LED 1, Online LED, Fault LED, Interpretation, Do not remove the drive. Removing a drive may
View all HP Xw25p manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 38 highlights
Activity LED (1) On or flashing On Flashing Off Off Online LED Fault LED (2) (3) Flashing Off Off Off Flashing Flashing Off On Off Off Interpretation Do not remove the drive. Removing a drive may terminate the current operation and cause data loss. The drive is rebuilding or undergoing capacity expansion. Do not remove the drive. The drive is being accessed, but (1) it is not configured as part of an array; (2) it is a replacement drive and rebuild has not yet started; or (3) it is spinning up during the POST sequence. Do not remove the drive. Removing a drive may cause data loss in non-fault-tolerant configurations. One or more of the following conditions may exist: • The drive is part of an array being selected by an array configuration utility • Drive Identification has been selected in HP SIM • The drive firmware is being updated The drive has been placed offline due to hard disk drive failure or subsystem communication failure. You may need to replace the drive. One or more of the following conditions may exist: • The drive is not configured as part of an array • The drive is configured as part of an array, but it is a replacement drive that is not being accessed or being rebuilt yet • The drive is configured as an online spare If the drive is connected to an array controller, you may replace the drive online. Server component identification 38