Honeywell DH65DG115 User Guide - Page 8

Plumbing, Terminal Description - security

Page 8 highlights

Installation Guide Plumbing Connect 1/2-in. drain tube to male connection drain outlet. Secure drain tube to connector with hose clamp. Run drain hose continuously downhill to an approved drain or condensate pump. Terminal Description CAUTION: Low-voltage Hazard. Can cause equipment damage. Disconnect HVAC equipment before beginning installation. A four-block wiring terminal is located on the exhaust end of TrueDRY. * Note: Outer screws secure block to TrueDRY DH65. Not for wiring. DHUM: Compressor and fan operation for dehumidification. COMPRESSOR RELAY CONTACTS 4 6 (NO) COMPRESSOR CS R COMPRESSOR CAPACITOR 5 (NO) 1 (NC) FAN MOTOR FAN RELAY CONTACTS 9 4 8 REMOTE FAN RELAY CONTACTS 12 1 3 (DEHUMID) DEHUMID FAN CAPACITOR TIMER MOTOR 2 115 VAC TRANSFORMER 24 VAC 4 DEFROST VARISTOR (C) THERMOSTAT COMPRESSOR RELAY COIL TIMER 0 1 R: FAN: C: 24V common. Fan activation only for ventilation. External accessory control (motorized damper, dehumidistat). 1 (AUTO) FAN RELAY COIL 2 ON (3) (NC) OVERFLOW SAFETY SWITCH (NO) 13 FAN 14 2 (FAN) REMOTE FAN RELAY COIL 1 (R) 13 OVERFLOW 14 INDICATOR LIGHT 1 2 3 4 (DEHUM) (R) (FAN) (C) HUMIDITY REMOVAL FAN ACCESSORY M27456B 69-2089EFS-08 6 69-2089EFS_D.indd 6 9/22/2008 10:02:35 AM

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

Installation Guide
69-2089EFS—08
6
Connect 1/2-in. drain tube to male connection drain
outlet. Secure drain tube to connector with hose clamp.
Run drain hose continuously downhill to an approved
drain or condensate pump.
Plumbing
Terminal Description
CAUTION: Low-voltage Hazard.
Can cause equipment damage.
Disconnect HVAC equipment before beginning
installation.
A four-block wiring terminal is located on the exhaust end of
TrueDRY.
*
Note:
Outer screws secure block to TrueDRY DH65. Not for wiring.
DHUM:
Compressor and fan operation for dehumidification.
R:
24V common.
FAN:
Fan activation only for ventilation.
C:
External accessory control (motorized damper,
dehumidistat).
M27456B
1
(
DEHUM
)
2
(R)
3
(FAN)
4
(C)
OVERFLOW
SAFETY
SWITCH
(NO)
(NC)
1
(R)
2
(FAN)
OVERFLOW
INDICATOR
LIGHT
REMOTE FAN
RELAY COIL
FAN
13
14
13
14
FAN RELAY
COIL
2
0
1
COMPRESSOR
RELAY COIL
TIMER
1
(AUTO)
DEFROST
THERMOSTAT
24 VAC
DEHUMID
(DEHUMID)
3
4
(C)
1
2
TIMER
MOTOR
TRANSFORMER
FAN
MOTOR
115 VAC
1 (NC)
9
5
(NO)
FAN RELAY
CONTACTS
4
12
8
REMOTE
FAN RELAY
CONTACTS
COMPRESSOR
RELAY CONTACTS
4
6 (NO)
FAN
CAPACITOR
COMPRESSOR
CAPACITOR
COMPRESSOR
C
S
R
ON
(3)
VARISTOR
HUMIDITY
REMOVAL
FAN
ACCESSORY
69-2089EFS_D.indd
6
9/22/2008
10:02:35 AM