Honeywell HCCM474M User Manual - Page 33

Blens Installation And Adjustment, Continued

Page 33 highlights

LENS INSTALLATION AND ADJUSTMENT, CONTINUED DC type lens ; Set lens switch to DC. Connect the lens cable of a DC (galvanometric) type lens. If the plug on the cable is of a different type, replace it with the provided 4-pin iris plug. Damping coil (-) Drive coil (+) 1 3 Damping coil (+) 2 4 Pin Assignment : DC type (4-pin) Drive coil (-) 1 3 Pin No. Signal 1 Damping coil (-) 2 Damping coil (+) 3 Drive coil (+) 4 Drive coil (-) 2 4 After installing the connector plug, connect it to the lens connector on the rear panel of camera. REV. B 33 HCMU000878 12/29/03

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41

REV.
B
33
HCMU000878
12/29/03
LENS INSTALLATION AND ADJUSTMENT, CONTINUED
DC type lens ; Set lens switch to DC.
Connect the lens cable of a DC (galvanometric) type lens. If the plug on the cable is of a
different type, replace it with the provided 4-pin iris plug.
1
2
4
3
Pin Assignment : DC type (4-pin)
Pin No.
Signal
1
Damping coil (-)
2
Damping coil (+)
3
Drive coil (+)
4
Drive coil (-)
Damping coil (-)
Damping coil (+)
Drive coil (+)
Drive coil (-)
1
3
2
4
After installing the connector plug, connect it to the lens connector on the rear
panel of camera.