Honeywell HW7500E Service Manual - Page 15

HW5500 & HW5500L - a

Page 15 highlights

HW5500 & HW5500L FIGURE 3-3: HW5500 & HW5500L Wiring Diagram Honeywell Portable Electrical Generator Service Manual ENGINE FUEL CUTOUT SOLENOID OIL SHUTDOWN SWITCH OIL ALERT SENDER SPARK PLUG G/W Y Y Bl Y IGNITION COIL Bl Bl ENGINE BLOCK gg ALTERNATOR NOTE: Alternator is mechanically connected to the engine block providing ground connection between the engine block and the alternator frame. FUEL CUTOUT WINDING FIELD WINDING EXCITER WINDING MAIN WINDING 120 VAC MAIN 120 VAC WINDING Br Br W R Lg W Bu Bu AVR R Bu Br W R Bu Br W ALTERNATOR 5A FUSE MAGNETIC AC BREAKER 21A WIRING DIAGRAMS www.honeywellgenerators.com Bu G/W Bl Y/G Y/G IG E Bl Bu G/W OFF ON Bl - Black Bu - Blue Br - Brown G/W - Green / White Lg - Light Green R - Red Y - Yellow Y/G - Yellow / Green W - White ENGINE CONTROL SWITCH ON/OFF SWITCH PANEL CONTROL PANEL THERMAL AC BREAKER 20A THERMAL AC BREAKER 20A W X W Y G DUPLEX 5-20R G DUPLEX 5-20R W X W Y G G Y/G W X Y TWIST-LOCK L14-30R G GROUND TERMINAL 3-5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

Honeywell Portable Electrical Generator Service Manual
www.honeywellgenerators.com
3-5
WIRING DIAGRAMS
HW5500 & HW5500L
FIGURE 3-3:
HW5500 & HW5500L Wiring Diagram
G
Y
W
X
ALTERNATOR
CONTROL PANEL
ENGINE
OIL ALERT
SENDER
SPARK
PLUG
OIL
SHUTDOWN
SWITCH
IGNITION
COIL
ENGINE BLOCK
Y
Y
Bl
Y
Bl
Bl
ENGINE
CONTROL
SWITCH
Bl
Bu
E
IG
GROUND
TERMINAL
DUPLEX 5-20R
Y/G
THERMAL
AC BREAKER
20A
G
W
X
FIELD
WINDING
MAIN
WINDING
EXCITER
WINDING
AVR
W
R
W
Lg
Bu
Bu
120 VAC
ALTERNATOR
Bl - Black
Bu - Blue
Br - Brown
G/W - Green / White
Lg - Light Green
R - Red
Y - Yellow
Y/G - Yellow / Green
W - White
THERMAL
AC BREAKER
20A
NOTE:
Alternator is mechanically connected
to the engine block providing ground
connection between the engine block
and the alternator frame.
ON/OFF SWITCH PANEL
G
W
X
DUPLEX 5-20R
G
W
Y
G
W
Y
MAIN
WINDING
Br
W
R
Bu
Br
W
R
Bu
FUEL
CUTOUT
WINDING
5A FUSE
G/W
G/W
TWIST-LOCK
L14-30R
Y/G
Br
Br
MAGNETIC
AC BREAKER
21A
120 VAC
OFF
ON
Bu
Bl
G/W
Y/G
FUEL CUTOUT
SOLENOID