Honeywell T7516B Owner's Manual - Page 61
Troubleshooting - air filters
View all Honeywell T7516B manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 61 highlights
Troubleshooting IF... THEN... Display does not come on. • There is no power being supplied to the thermostat. Check fuse or circuit breaker. • Check the furnace air filter. A dirty filter will choke the airflow causing safety shutdown; replace or clean, if necessary. Temperature display does • You have reached the thermostat setting limit. The setting not go lower than 45°F or range is 45°F to 88°F. higher than 88°F during programming. Temperature change occurs at the wrong time. • Check programming for the period in question. Be sure the time-including AM/PM indication-is correct. Reprogram if necessary. • Keep in mind that it takes time for the system to recover. Refer to the Recovery from Setback section for details. (continued) 61 69-1611