Hoover H3000 Manual - Page 7

Recovery Tank lower tank, Automatic Shut-Off - floormate hard floor cleaner

Page 7 highlights

2-10 H 2.0 oz./60ml. Turn cap (H) upside down to serve as a measuring cup. 2-11 2.0 oz./60ml. Using cap, measure 2 oz. of applicable concentrate formulated for use with the 'FloorMate' hard floor cleaner. For best results, use Machine Formula LYSOL® Floor Cleaning Concentrate when cleaning floor surfaces such as vinyl, ceramic and other tiles, and linoleum. Use Machine Formula OLD ENGLISH® Wood Floor Cleaning Concentrate for wood floors when cleaning laminate wood, polyurethane sealed wood or other wood floors that can normally be cleaned using water. Check for worn spots or joint separations before using, as these conditions could lead to damaged flooring when using water to clean floor. Both of these concentrates have been specifically formulated to resist excessive foaming and other undesirable effects when used in your 'FloorMate' Cleaner. DO NOT use cleaning concentrates that contain pine or solvent based ingredients. CAUTION: Machine Formula LYSOL® Floor Cleaning Concentrate and OLD ENGLISH® Wood Floor Cleaning Concentrate cannot be used in Hoover SteamVac™ products. Doing so could damage your SteamVac™. 2-12 I FILL 2-13 J 2.0 oz./60ml. K Pour cleaning concentrate into tank. Fill tank to fill line (I) (1 quart) with warm water. If rubber ring (J) on cap has become dislodged, reposition it with uneven side against ledge (K) as shown. 2-14 Replace cap. Rotate cap clockwise until it locks in place. Cap must be locked in place for proper performance and to prevent leaking. 2-15 Recovery Tank (lower tank) The recovery tank holds both dry debris and dirty cleaning solution that is picked up from the floor surface. Position bottom of tank into cleaner. Press latch and snap tank into place. Automatic Shut-Off An automatic suction shut-off is built into the recovery tank to prevent the tank from overflowing. When the shut-off activates, the cleaner will not pick up debris and the sound of the motor will change. There are two reasons the shut-off will activate. 1. Recovery tank is full - Turn the cleaner off and empty the recovery tank. 2. The handle was raised to the upright position while the motor was running - Turn cleaner off. Wait a moment for the shut-off to reset. Turn cleaner on and continue cleaning. Continued 7

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14

FILL
I
7
2-12
2.0 oz./60ml.
2-13
2.0 oz./60ml.
2.0 oz./60ml.
Turn cap (H) upside down to serve
as a measuring cup.
2-10
Using cap, measure 2 oz. of applica-
ble concentrate formulated for use
with the ‘FloorMate’ hard floor cleaner.
2-11
Pour cleaning concentrate into tank.
Fill tank to fill line (I) (1 quart) with
warm water.
If rubber ring (J) on cap has become
dislodged, reposition it with uneven
side against ledge (K) as shown.
Use Machine Formula OLD ENG-
LISH® Wood Floor Cleaning Concen-
trate for wood floors when cleaning
laminate wood, polyurethane sealed
wood or other wood floors that can
normally be cleaned using water.
Check for worn spots or joint separa-
tions before using, as these condi-
tions could lead to damaged flooring
when using water to clean floor.
Both of these concentrates have been
specifically formulated to resist
excessive foaming and other undesir-
able effects when used in your ‘Floor-
Mate’ Cleaner.
DO NOT use cleaning concentrates
that contain pine or solvent based
ingredients.
K
J
H
For best results, use Machine Formula
LYSOL® Floor Cleaning Concentrate
when cleaning floor surfaces such as
vinyl, ceramic and other tiles, and
linoleum.
Continued
CAUTION: Machine Formula
LYSOL® Floor Cleaning Concen-
trate and OLD ENGLISH® Wood
Floor Cleaning Concentrate cannot
be used in Hoover SteamVac™
products. Doing so could damage
your SteamVac™.
Replace cap. Rotate cap clockwise
until it locks in place. Cap must be
locked in place for proper perfor-
mance and to prevent leaking.
2-14
2-15
Recovery Tank (lower tank)
The recovery tank holds both dry
debris and dirty cleaning solution that
is picked up from the floor surface.
Automatic Shut-Off
An automatic suction shut-off is built
into the recovery tank to prevent the
tank from overflowing.
When the shut-off activates, the clean-
er will not pick up debris and the
sound of the motor will change.
There are two reasons the shut-off will
activate.
1. Recovery tank is full -
Turn the
cleaner off and empty the recovery
tank.
2. The handle was raised to the
upright position while the motor
was running -
Turn cleaner off. Wait a
moment for the shut-off to reset. Turn
cleaner on and continue cleaning.
Position bottom of tank into cleaner.
Press latch and snap tank into place.