    TurboPower™ Upright Vacuum Cleaner Owner's Manual English § pp. 1-14 Spanish § pág. 15-22 French § p. 23-29 Review this manual before operating cleaner. ®
  • Hoover U5415-900 | Owners Manual - Page 2
    , or dropped into water, take it to a Hoover Factory Service Center or Authorized Hoover Warranty Service Dealer (Depot). • Use vacuum cleaner only for its intended use as described in the instructions. Use only attachments recommended by The Hoover Company; others may cause hazards. Save these
  • Hoover U5415-900 | Owners Manual - Page 3
    instruction steps in order. The assembled cleaner will look like this drawing. If you need assistance with any step of the assembly, call 1-800-944-9200 for an automated referral of authorized service 1-1 Remove all parts from carton and identify each item shown. Make sure all parts, especial small
  • Hoover U5415-900 | Owners Manual - Page 4
    FRONT UP FRONT Handle assembly 1-2 C 1-3 F G D B A Place upper (A) and lower (B) handle sections on a flat surface with cord hooks (C) on top. With hands on sides of handle sections, push sections together firmly until they "click" into place. *Do not press against the rod (D) extending from
  • Hoover U5415-900 | Owners Manual - Page 5
    1-11 1-12 1-13 Push bolt into hole on lower front of handle. If bolt will not go through hole easily, check the following: the bracket is properly positioned the handle is pushed completely down Place nut in recessed area at back of handle. Hold nut in place while tightening bolt securely with a
  • Hoover U5415-900 | Owners Manual - Page 6
    X With smaller end toward bottom, snap wand into clips on rack. Position dusting brush (W) into rack as shown. Place furniture nozzle (X) on lip on lower part of rack and snap into place. Continued § 6
  • Hoover U5415-900 | Owners Manual - Page 7
    place. Remove rectangular foam retainer (Z), if present, (part of protective packing material) located under the handle release lever the agitator brush roll will continue to rotate while cleaner handle is in upright position. Avoid tipping cleaner or setting it on furniture, fringed area rugs or
  • Hoover U5415-900 | Owners Manual - Page 8
    turn cleaner on, push switch up. To turn cleaner off, push switch down. Plug cord into electrical outlet. Turn cleaner on and, with handle in upright position, pull back on handle until front of cleaner is lifted off the carpet. This insures that the paper bag is inflated. Handle positions The
  • Hoover U5415-900 | Owners Manual - Page 9
    sides of nozzle to remove dirt in carpet near baseboards and furniture. Guide either side of nozzle parallel to edge of carpet or furniture. 2- OFF before attaching or removing hose. With cleaner handle in upright position, open hose door and insert hose connector until locked in Manual. Continued §
  • Hoover U5415-900 | Owners Manual - Page 10
    or loosen connection. Use cleaning tools with cleaner handle in upright position. Clearing obstructions To check for obstructions, first turn cleaner obstruction is found and a problem persists, contact your Hoover Factory Service Center or an Authorized Warranty Service Dealer (Depot). 3.
  • Hoover U5415-900 | Owners Manual - Page 11
    door. The headlight 3-4 3-5 (some models only) What to buy This cleaner uses a 12 volt, wedge base type 912 bulb, Hoover Part No.27313-101. The belt The belt on your HOOVER cleaner causes the agitator to rotate and is important for the effective operation of the cleaner. The belt is located
  • Hoover U5415-900 | Owners Manual - Page 12
    3-8 3-9 3-10 E D C Positioning belt and agitator Slip agitator through new belt (with lettering toward outside of cleaner) and position belt in belt guide (C). Push end of belt into opening in cleaner body. Reposition agitator making sure to align flat sides of projection (D) on belt end of
  • Hoover U5415-900 | Owners Manual - Page 13
    row of brushes Hoover part No. 48414-051, Double row of brushes Hoover part No. 48414-049 fuse/tripped breaker. • Replace fuse/reset breaker. Problem: Cleaner won't pick up Possible cause Possible solution Hoover Factory Service Center or an Authorized Hoover Warranty Service Dealer (Depot). 13
  • Hoover U5415-900 | Owners Manual - Page 14
    To obtain approved HOOVER service and genuine HOOVER parts, locate the nearest Hoover Factory Service Center or Authorized Hoover Warranty Service Dealer(Depot) by: • checking the Yellow Pages under "Vacuum Cleaners -Household" OR- • checking the list of Factory Service Centers provided with this
  • Hoover U5415-900 | Owners Manual - Page 15
    HOOVER y son marcas registradas HOOVER et sont des marques déposées HOOVER and are registered trademarks ® 1/00 U5046-930 Litho USA 56511-A79
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15

TurboPower™
Upright Vacuum
Cleaner
Owner’s Manual
English
pp. 1-14
Spanish
pág. 15-22
French
p. 23-29
Review this manual before
operating cleaner.
®