Hunter 40170 Owner's Manual - Page 27
Adjust, Span Adjust
View all Hunter 40170 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 27 highlights
Indicators and Adjustments, cont. Your thermostat is preset to cycle your system off and on at 1oF above and below the Set Temperature. For maximum system efficiency and a sustained comfortable temperature your system should cycle 3 - 5 times per hour. If your system is cycling either too often or not often enough, then use a small Phillips-head screwdriver and the Span Adjust to change the cycle time. 1. Remove the top cover from the thermostat. 2. To make your system run LONGER, turn the Span Adjust clockwise. 3. To make your system run SHORTER, turn the Span Adjust counter clockwise. 4. Reattach the top cover to the thermostat. Note: The Span range is 0.6oF - 3oF. The Span setting remains the same in both the Heat and Cool modes and can be changed regardless of what position the System Switch is in. 27