Icom IC-M72 Instruction Manual - Page 26

DLCD contrast selection DAuto power save function DSelf check function

Page 26 highlights

7 SET MODE D LCD contrast selection " " The contrast of the LCD can be selected from Hi (default) and Lo. Push High contrast (default) Low contrast D Auto power save function " " The auto power save function reduces current drain by deac- tivating the receiver circuit for preset intervals. • ON : The power save function is turned ON. The power save func- tion will activate when no signal is received, and no operation is performed for 5 sec. • OFF : The power save function is turned OFF. Power save ON (default) Push Power save OFF D Self check function " " The self check function informs you in case a problem is found with the radio. Self check automatically and quickly runs through its diagnostic steps each time the radio is turned ON. Afterwards, the radio switches to normal operation mode. • Temperature : Outside of -35°C to +73°C; -31°F to +163°F (approx.) • Connected battery voltage • Water intrusion Push Self check OFF (default) Self check ON When any of the bellow error messages appear, see the troubleshooting section of this document for advice. (p. 30) Battery voltage error Temperature error Water intrusion 20

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40

20
7
SET MODE
D
LCD contrast selection
The contrast of the LCD can be selected from Hi (default) and
Lo.
D
Auto power save function
The auto power save function reduces current drain by deac-
tivating the receiver circuit for preset intervals.
ON
: The power save function is turned ON. The power save func-
tion will activate when no signal is received, and no operation
is performed for 5 sec.
OFF : The power save function is turned OFF.
D
Self check function
The self check function informs you in case a problem is
found with the radio. Self check automatically and quickly
runs through its diagnostic steps each time the radio is turned
ON. Afterwards, the radio switches to normal operation mode.
Temperature : Outside of
35
°
C to +73
°
C;
31
°
F to +163
°
F
(approx.)
Connected battery voltage
Water intrusion
When any of the bellow error messages appear, see the trou-
bleshooting section of this document for advice.
(p. 30)
Battery voltage error
Temperature error
Water intrusion
Push
Self check OFF
(default)
Self check ON
Push
Power save ON
(default)
Power save OFF
Push
High contrast (default)
Low contrast