Intel SBX82 User Guide - Page 32

Table 3. SW4 Light Path Diagnostics LED locations

Page 32 highlights

Table 3. SW4 Light Path Diagnostics LED locations LED error NMI MIS SBRD TEMP Light Path Diagnostics LED Ligh Path Diagnostics button (SW4) Action Ceck the error log for additional information. Reboot the blade server. If the error still exists, replace the system board. Check the processors to make sure they are at the same speed. Reboot the blade server. If the error still exists, replace the system board. Check the SBCE unit blowers and air inlets. Check the room temperature. Check the Light Path Diagnostics LED for errors Press SW4 to locate faults on the system board. If the processor or memory LED is lit, reseat the component. If the LED remains lit, replace the defective component. See "Diagnosing problems using Light Path Diagnostics" on page 65 for information on what action to take if there is a component error. 18 Intel Server Compute Blade SBX82 Installation and User's Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88

18
Intel Server Compute Blade SBX82 Installation and User’s Guide
See “Diagnosing problems using Light Path Diagnostics” on page 65 for information on what
action to take if there is a component error.
Table 3. SW4 Light Path Diagnostics LED locations
LED error
Action
NMI
Ceck the error log for additional information. Reboot the blade
server. If the error still exists, replace the system board.
MIS
Check the processors to make sure they are at the same
speed.
SBRD
Reboot the blade server. If the error still exists, replace the
system board.
TEMP
Check the SBCE unit blowers and air inlets. Check the room
temperature.
Light Path Diagnostics LED
Check the Light Path Diagnostics LED for errors
Ligh Path Diagnostics button (SW4)
Press SW4 to locate faults on the system board. If the
processor or memory LED is lit, reseat the component. If the
LED remains lit, replace the defective component.