Table 3. SW4 Light Path Diagnostics LED locations
UPC - 675900686984
View all Intel SBX82 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
Table 3. SW4 Light Path Diagnostics LED locations LED error NMI MIS SBRD TEMP Light Path Diagnostics LED Ligh Path Diagnostics button (SW4) Action Ceck the error log for additional information. Reboot the blade server. If the error still exists, replace the system board. Check the processors to make sure they are at the same speed. Reboot the blade server. If the error still exists, replace the system board. Check the SBCE unit blowers and air inlets. Check the room temperature. Check the Light Path Diagnostics LED for errors Press SW4 to locate faults on the system board. If the processor or memory LED is lit, reseat the component. If the LED remains lit, replace the defective component. See "Diagnosing problems using Light Path Diagnostics" on page 65 for information on what action to take if there is a component error. 18 Intel Server Compute Blade SBX82 Installation and User's Guide