Invacare IRC5LX Owners Manual

Invacare IRC5LX Manual

Invacare IRC5LX manual content summary:

  • Invacare IRC5LX | Owners Manual - Page 1
    's Manual Platinum™ Series XL, 5, 10 Oxygen Concentrators Standard, with SensO2®and HomeFill® Invacare 5 with SensO2 Model IRC5LXO2 Invacare 10 with SensO2 Model IRC10LXO2 Invacare 5 Model IRC5LX Invacare 10 Model IRC10LX Dealer: This manual MUST be given to the end user. User: Before using this
  • Invacare IRC5LX | Owners Manual - Page 2
    WARNING ƽ WARNING DO NOT use this product or any available optional equipment without first completely reading and understanding these instructions and any additional instructional material such as owner's manuals, service manuals or instruction sheets supplied with this product or optional
  • Invacare IRC5LX | Owners Manual - Page 3
    Storage 12 SECTION 4-TYPICAL PRODUCT PARAMETERS 13 SECTION 5-OPERATING INSTRUCTIONS ....... 16 Introduction 16 Select a Location 16 Set-Up of the Concentrator 21 Front Panel Indicators - Units without SensO2 22 Initial Startup of the Concentrator 22 Part No 1118353 3 Platinum™ Series
  • Invacare IRC5LX | Owners Manual - Page 4
    at warranty.invacare.com Please have your model number and purchase date available to complete your registration. Any registration information you submit will only be used by Invacare Corporation and protected as required by applicable laws and regulations. Platinum™ Series 4 Part No 1118353
  • Invacare IRC5LX | Owners Manual - Page 5
    used in this manual without notice. Ꮨ DANGER DO NOT SMOKE while using this device. Keep all matches, lighted cigarettes or this product is located and away from where oxygen is being delivered. NO SMOKING signs should be and burn with great intensity in oxygen enriched air. Failure to observe this
  • Invacare IRC5LX | Owners Manual - Page 6
    in which he/she practices to use or order the use of this device." Invacare recommends an alternate source of supplemental oxygen in the event of a power equipment is to be used as an oxygen supplement and is not considered life supporting or life sustaining. Platinum™ Series 6 Part No 1118353
  • Invacare IRC5LX | Owners Manual - Page 7
    LABEL LOCATION IRC5LX and IRC10LX HomeFill II Compatible Operating Instructions (See Operator's Manual) Alarms (See Operator's Manual) I/O WARNING - RISK OF FIRE NO SMOKING - Keep ALL sources of ignition out of the room in which this product is located and away from areas where oxygen is being
  • Invacare IRC5LX | Owners Manual - Page 8
    oxygen concentrator, tubing and connections, and all other oxygen equipment. DO NOT use any lubricants unless recommended by Invacare. Avoid creation of any spark near medical oxygen equipment. This includes sparks from static electricity created by any type of friction. Platinum™ Series 8 Part
  • Invacare IRC5LX | Owners Manual - Page 9
    NOT move or relocate concentrator by pulling on the power cord. NEVER drop or insert any object or liquid into any opening. Invacare recommends that Crush‐Proof oxygen tubing be used with this product and not exceed 15.2 m (50 ft) in length. There are no user serviceable parts. This does not include
  • Invacare IRC5LX | Owners Manual - Page 10
    , or increase the separation between the equipment. Connect the equipment into an outlet on a circuit different from that to which the other device(s) is connected. Platinum™ Series 10 Part No 1118353
  • Invacare IRC5LX | Owners Manual - Page 11
    HomeFill ownerʹs manual, part number 1100873, for connection and operating instructions. When not in use, the plug provided with the concentrator should be inserted into the outlet fitting. For more information about the HomeFill, contact your Invacare dealer. Part No 1118353 11 Platinum™ Series
  • Invacare IRC5LX | Owners Manual - Page 12
    Inspection Inspect/examine exterior of the oxygen concentrator for nicks, dents, scratches or other damages. Inspect all components. Storage 1. Store the repackaged oxygen concentrator in a dry area. 2. DO NOT place objects on top of repackaged concentrator. Platinum™ Series 12 Part No 1118353
  • Invacare IRC5LX | Owners Manual - Page 13
    ft (4000 meters) below 90% efficiency *Oxygen Output Concentration Levels: All 5LXO2/5LX models 87% to 95.6% for flows ranging 0.5 to 5 L/min and all 10LXO2/10LX models 87% to 95.6% for flows ranging 2 L to 10 L/min Maximum Outlet Pressure: Platinum 5 and XL: 5 psi ± 0.5 psi (34.5 kPa ± 3.45 kPa
  • Invacare IRC5LX | Owners Manual - Page 14
    flow when back pressure of 7kPa is applied: Filters: Safety System: Width: Height: Depth: Weight: Shipping Weight: Platinum 5 and XL - 0.5 to 5 L/min For flowrates less than 1 L/min, we recommend the use of the Invacare Pediatric Flowmeter IRCPF16 Accessory. Platinum 10 - 2 L/min to 10 L/min
  • Invacare IRC5LX | Owners Manual - Page 15
    Oxygen Output Temperature: Cabinet: Regulatory Listing: Electrical: Placement: Tubing: Relative Humidity: Time of Operation: Recommended Storage and Shipping Temperature: 50°F - 95°F (10°C - 35°C) at 20-60% relative humidity Platinum 5 and XL (DO NOT pinch). Platinum 10: Recommended use up to 50 ft
  • Invacare IRC5LX | Owners Manual - Page 16
    will show you how to use your oxygen concentrator. He/She should be contacted with any questions or problems regarding your oxygen concentrator. This owner's manual will tell you about your concentrator and will serve as a reference as you use your concentrator. Select a Location ƽ WARNING NEVER
  • Invacare IRC5LX | Owners Manual - Page 17
    oxygen input and output connections. Water from the humidifier bottle will travel through the cannula back to the patient. NOTE: For this procedure, refer to FIGURE 5.1, FIGURE 5.2 and FIGURE 5.3 on page 18 and FIGURE 5.4 on page 19. NOTE: For Platinum 5, XL ‐ recommended humidifiers are: Invacare
  • Invacare IRC5LX | Owners Manual - Page 18
    SECTION 5-OPERATING INSTRUCTIONS Humidifier Bottle FIGURE 5.2 Humidifier Compartment 3. Remove the filter access door located on the side of the concentrator. Insert a flathead screwdriver in the plate groove on the top edge of the filter access door and gently pry the filter access door open.
  • Invacare IRC5LX | Owners Manual - Page 19
    INSTRUCTIONS 7. Attach oxygen tubing from the humidifier bottle to oxygen outlet connector on the oxygen concentrator (FIGURE 5.4). 8. Attach the cannula/patient supply tubing to the humidifier bottle outlet (FIGURE 5.4). 9. After assembly, ensure that oxygen Part No 1118353 19 Platinum™ Series
  • Invacare IRC5LX | Owners Manual - Page 20
    INSTRUCTIONS Flowrate If the flowrate on the flowmeter ever falls below 0.5 L/min for Platinum 5 (1 L/min for Platinum 10) for more than about one minute, the LOW FLOW alarm L/min for Platinum 5 (1 L/min for Platinum 10), the LOW FLOW audible alarm will go off. NOTE: The use of some accessories
  • Invacare IRC5LX | Owners Manual - Page 21
    INSTRUCTIONS Front Panel Indicators - Units with SensO2 NOTE: For this procedure, refer to FIGURE 5.7. The SensO2 feature monitors the purity of oxygen generated by the oxygen concentrator. If purity falls below factory preset standards, indicator lights on the control panel will illuminate. OXYGEN
  • Invacare IRC5LX | Owners Manual - Page 22
    INSTRUCTIONS Front Panel Indicators - Units without SensO2 NOTE: For this procedure, refer to FIGURE 5.8. Auto Shut - Down Use Backup RED Call Supplier Normal I/O GREEN FIGURE 5.8 Front Panel Indicators - Units without SensO2 Initial Startup of the Concentrator NOTE: Concentrator may be used
  • Invacare IRC5LX | Owners Manual - Page 23
    cabinet. 1. Remove each filter and clean at least once a week depending on environmental conditions. NOTE: Environmental conditions that may require more frequent cleaning of the filters include but are not limited to: high dust, smoking, air pollutants, etc. Part No 1118353 23 Platinum™ Series
  • Invacare IRC5LX | Owners Manual - Page 24
    Filter Cleaning the Cabinet ƽ WARNING UNPLUG the concentrator when cleaning. To avoid electrical shock, DO NOT remove cabinet. Clean the cabinet with a mild household cleaner and non‐abrasive cloth or sponge. Cleaning the Humidifier NOTE: To clean the oxygen humidifier, follow the instructions
  • Invacare IRC5LX | Owners Manual - Page 25
    I RC Part No 1118353 FIGURE 6.2 Preventive Maintenance Record 25 PREVENTIVE MAINTENANCE RECORD INVACARE PLATINUM OXYGEN CONCENTRATOR ON EACH INSPECTION Record Date of Service Record Elapsed Hours On Hour Meter Clean Cabinet Filter(s) Check Prescribed L/min. Flow Rate EVERY 4,380 HOURS FOR IRC5LX
  • Invacare IRC5LX | Owners Manual - Page 26
    7-TROUBLESHOOTING GUIDE SYMPTOM: PROBABLE CAUSE: SOLUTION: Alarm: SHORT BEEPS, LONG PAUSE Main Power Loss: 1. Power cord NOT plugged in. 1. Insert plug into outlet. 2. No power at outlet. 2. Inspect house circuit break- Concentrator ers or fuses. If problem recurs, NOT operating, use
  • Invacare IRC5LX | Owners Manual - Page 27
    and 10LXO2 SensO2 models. 3. Flowmeter set too low: 3. Check flowmeter is set to 0.5 L/min (or less) for 1.0 L/min. or more. Platinum 5; 1.0 L/min (or less) for Platinum 10. 4. Unit overheating due to 4.a. Remove and clean cabinet blocked air intake. filters. 4b. Move concentrator at least
  • Invacare IRC5LX | Owners Manual - Page 28
    NOTES NOTES Platinum™ Series 28 Part No 1118353
  • Invacare IRC5LX | Owners Manual - Page 29
    NOTES NOTES Part No 1118353 29 Platinum™ Series
  • Invacare IRC5LX | Owners Manual - Page 30
    warranty gives you specific legal rights and you may also have other legal rights which may vary from state to state. Invacare Corporation warrants its Platinum XL Oxygen Concentrators when purchased new and unused to be free from defects in materials and workmanship for a period of five years from
  • Invacare IRC5LX | Owners Manual - Page 31
    component part(s) to either Invacare Corporation's plant or service center as specified by Invacare Corporation in advance. Defective component part(s) MUST be returned for warranty inspection using the TO COMPLY WITH STATE/PROVINCIAL LAWS AND REQUIREMENTS. Part No 1118353 31 Platinum™ Series
  • Invacare IRC5LX | Owners Manual - Page 32
    Way Elyria, Ohio USA 44036-2125 800-333-6900 Technical Services 800-832-4707 www.invacare.com Trademarks are identified by ™ and ®. All trademarks are owned by or licensed to Invacare Corporation or its subsidiaries unless otherwise noted. © 2009 Invacare Corporation Part No 1118353 Rev J - 4/09
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

Dealer:
This manual MUST be given to the end
user.
User:
Before using this product, read this manual
and save for future reference.
Operator’s Manual
For more information regarding
Invacare products,
parts, and services,
please visit www.invacare.com
Platinum
Series
XL, 5, 10
Oxygen Concentrators Standard,
with
SensO
2
®
and HomeFill
®
Invacare 5
with
SensO
2
Model IRC5LXO2
Invacare 5
Model IRC5LX
Invacare 10
with
SensO
2
Model IRC10LXO2
Invacare 10
Model IRC10LX