Invacare RPS350-2 Owners Manual - Page 13

Operation, Locking/Unlocking the Rear Casters, Raising/Lowering the Patient Lift - manual

Page 13 highlights

SECTION 3- OPERATION SECTION 3-OPERATION ƽ WARNING DO NOT attempt to transfer a patient without approval of the patient's physician, nurse, or medical assistant. Thoroughly read the instructions in this owner's manual, observe a trained team of experts performing the lifting procedures and then perform the entire lift procedure several times with proper supervision and a capable individual acting as a patient. The legs of the stand up lift MUST be in the maximum open position for optimum stability and safety. If the patient is in a sling and it becomes necessary to move through a narrow passage, close the legs of the stand up lift only as long as it takes to move through the passage. When the stand up lift is through the passage, return the legs to the maximum open position. NOTE: The use of the patient lift by one assistant should be based on the evaluation of the health care professional for each individual case. Locking/Unlocking the Rear Casters • Refer to Detail "A" of Figure 3.1. Raising/Lowering the Patient Lift NOTE: For this procedure, refer to Detail "B". • To Raise the Patient Lift: Press the up () button on the hand control. NOTE: If the patient lift is raised to the highest level, it may be necessary to pull down gently on the lift arms before the mast will begin to lower. Pull down gently on both arms at the same time to avoid making the lift unstable. • To Lower the Patient Lift: Press the down button () on the hand control. Closing/Opening the Legs • To Close the Legs: Press the close button on the hand control. • To Open the Legs: Press the open button on the hand control. Using the Emergency Stop NOTE: For this procedure, refer to Detail "C". • Push the RED emergency button in to stop the lift arms from raising or lowering. • To reset, rotate the emergency button clockwise. DETAIL "A" Step Here to Lock Step Here to Unlock Locking Lever UNLOCKED LOCKED DETAIL "B" - HAND CONTROL DETAILS Up Button Legs Open Button Down Button Legs Close Button Hand Control DETAIL "C" - EMERGENCY STOP Emergency Button Push in to stop, turn clockwise to reset. Part No. 1145811 FIGURE 3.1 Operating the Patient Lift 13 Stand Up Patient Lift

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

SECTION 3—OPERATION
Part No. 1145811
13
Stand Up Patient Lift
SECTION 3— OPERATION
±
WARNING
DO NOT attempt to transfer a patient without approval of the patient’s physician, nurse, or medical
assistant. Thoroughly read the instructions in this owner’s manual, observe a trained team of experts
performing the lifting procedures and then perform the entire lift procedure several times with
proper supervision and a capable individual acting as a patient.
The legs of the stand up lift MUST be in the maximum open position for optimum stability and
safety. If the patient is in a sling and it becomes necessary to move through a narrow passage, close
the legs of the stand up lift only as long as it takes to move through the passage. When the stand up
lift is through the passage, return the legs to the maximum open position.
NOTE: The use of the patient lift by one assistant should be based on
the evaluation of the health care professional for each individual case.
Locking/Unlocking the Rear Casters
Refer to Detail “A” of Figure 3.1.
Raising/Lowering the Patient Lift
NOTE: For this procedure, refer to Detail “B”.
To Raise the Patient Lift:
Press the up
(
)
button on the hand control.
NOTE: If the patient lift is raised to the highest level, it may be
necessary to pull down gently on the lift arms before the mast will
begin to lower. Pull down gently on both arms at the same time to
avoid making the lift unstable.
To Lower the Patient Lift:
Press the down button
(
)
on the hand control.
Closing/Opening the Legs
To Close the Legs:
Press the close button on the hand control.
To Open the Legs:
Press the open button on the hand control.
Using the Emergency Stop
NOTE: For this procedure, refer to Detail “C”.
Push the RED emergency button in to stop the lift arms
from raising or lowering.
To reset, rotate the emergency button clockwise.
FIGURE 3.1
Operating the Patient Lift
DETAIL “B” - HAND CONTROL DETAILS
DETAIL “C” - EMERGENCY STOP
Down Button
Up Button
Hand Control
Emergency Button
Push in to stop,
turn clockwise
to reset.
Step Here
to Lock
Step Here
to Unlock
Locking
Lever
LOCKED
UNLOCKED
DETAIL “A”
Legs Close Button
Legs Open Button