SECTION 3-OPERATION Activating a Mechanical Emergency Release Primary Emergency Release NOTE: For this procedure, refer to FIGURE 3.2. NOTE: This procedure will bring the boom down if the hand control is not functioning properly. To activate the primary emergency release, insert the tip of a pen into the Emergency Down hole () in the control box. Secondary Emergency Release NOTE: For this procedure, refer to FIGURE 3.3. NOTE: All patient lift actuators are equipped with a mechanical emergency release. The mechanical release will enable the actuator to retract without power. NOTE: Use the primary emergency release first before using the secondary emergency release procedure. This procedure should only be used if the primary emergency release procedure is not functioning or is unreachable. NOTE: The lift MUST be under a load for the mechanical release to function. To activate the secondary emergency release, pull up on the RED emergency grip and pull down on the boom at the same time. Charging the Battery NOTE: For this procedure, refer to FIGURE 3.4. NOTE: Invacare recommends the battery be recharged daily to prolong battery life. NOTE: An audible alarm will sound when battery is low. 1. Lift UP on the handle on the back of the battery. 2. Lift the battery up and away from the control box. CAUTION Make sure there is an audible click when mounting battery on the battery charger. Otherwise, injury or damage may occur. Control Box Emergency Down Hole FIGURE 3.2 Primary Emergency Release RED Emergency Grip FIGURE 3.3 Secondary Emergency Release Battery Handle STEPS 1, 2, 4 and 5) 3. Place the battery on the battery charger. Push the top of the battery against the mounting bracket until there is an audible click. NOTE: The charge LED will illuminate. When charged, the LED will stop illuminating. NOTE: It will take approximately four hours to charge a battery that requires a full charge. 4. Lift UP on the handle on the back of the battery. 5. Lift the battery up and away from the battery charger. Battery Charger (STEP 3) Control Box (STEP 6) CAUTION Make sure there is an audible click when mounting battery on the battery charger. Otherwise, injury or damage may occur. 6. Place the battery on the control box. Push the top of the battery against the mounting bracket until there is an audible click. An audible "click" will be heard when properly installed (STEPS 3 and 6) FIGURE 3.4 Charging the Battery Stand Up Patient Lift 14 Part No. 1145811

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28

SECTION 3—OPERATION
Stand Up Patient Lift
14
Part No. 1145811
Activating a Mechanical Emergency
Release
Primary Emergency Release
NOTE: For this procedure, refer to FIGURE 3.2.
NOTE: This procedure will bring the boom down if the hand control
is not functioning properly.
To activate the primary emergency release, insert the tip of a
pen into the Emergency Down hole
(
)
in the control box.
Secondary Emergency Release
NOTE: For this procedure, refer to FIGURE 3.3.
NOTE: All patient lift actuators are equipped with a mechanical
emergency release. The mechanical release will enable the actuator to
retract without power.
NOTE: Use the primary emergency release first before using the
secondary emergency release procedure. This procedure should only
be used if the primary emergency release procedure is not functioning
or is unreachable.
NOTE: The lift MUST be under a load for the mechanical release to
function.
To activate the secondary emergency release, pull up on the
RED emergency grip and pull down on the boom at the same
time.
Charging the Battery
NOTE: For this procedure, refer to FIGURE 3.4.
NOTE: Invacare recommends the battery be recharged daily to
prolong battery life.
NOTE: An audible alarm will sound when battery is low.
1.
Lift UP on the handle on the back of the battery.
2.
Lift the battery up and away from the control box.
CAUTION
Make sure there is an audible click when mount-
ing battery on the battery charger. Otherwise,
injury or damage may occur.
3.
Place the battery on the battery charger. Push the top of the
battery against the mounting bracket until there is an
audible click.
NOTE: The charge LED will illuminate. When charged, the LED
will stop illuminating.
NOTE: It will take approximately four hours to charge a battery that
requires a full charge.
4.
Lift UP on the handle on the back of the battery.
5.
Lift the battery up and away from the battery charger.
CAUTION
Make sure there is an audible click when mount-
ing battery on the battery charger. Otherwise,
injury or damage may occur.
6.
Place the battery on the control box. Push the top of the
battery against the mounting bracket until there is an
audible click.
FIGURE 3.2
Primary Emergency Release
FIGURE 3.3
Secondary Emergency Release
FIGURE 3.4
Charging the Battery
Emergency Down
Hole
Control Box
RED Emergency Grip
Battery Charger
(STEP 3)
Control Box
(STEP 6)
An audible “click”
will be heard when
properly installed
(STEPS 3 and 6)
Handle
STEPS 1, 2, 4 and 5)
Battery