JVC VR-N1600UA Setup Guide - Page 18

Mounting to a Rack

Page 18 highlights

Getting Started Part Names and Functions (continued) Mounting to a Rack Rear I/O Terminals Terminal e[ALARM IN] 250 ms and above Make 250 ms and above Break Memo : ● Set the impedance at the output end to 10kK or below. Remarks Make Contact Input f[EMERGENCY] g[ALARM RESET] 250 ms and above Memo : ● Set the impedance at the output end to 10kK or below. Make Contact Input h[EXT REC IN] 250 ms and above Make Contact Input Memo : ● Set the impedance at the output end to 10kK or below. j[OPE ON/ OFF] 1 s and above Approx. 50 ms OPE ON OPE OFF Memo : ● Set the impedance at the output end to 10kK or below. Make Contact Input j[REC TALLY] k[ALARM OUT] l[WARNING OUT] m[OPTION OUT1] [OPTION OUT2] Make Output In Progress Break Output In Progress (External Pull-up Level) The make contact is formed using the individual output terminals and the COM terminal. Turning off the power of VR-N1600U/E switches the output of the output terminals to break. Auto Collector Output (DC15V, 10 mA and below) Use the supplied rack mount bracket to mount VR-N1600U/E to the EIA rack. 1 Mount the rack mount bracket using screw (1) ● Use the 4 screws (M4 x 10 mm) supplied to fasten VR-N1600U/E at the two sides. 2 Remove screws B of the foot (4 pcs) at the bottom ● Remove the foot. 3 Mount to the rack using screws C ● Use the 4 screws (M5 x 11 mm) supplied to fasten this unit to the rack. Rack Mount Bracket (4 Locations) Note : ● Do not place any object on the VR-N1600U/E unit that has been mounted to the rack. Doing so may cause it to lose balance and drop or fall, hence resulting in injuries or damages. ● When mounting 2 or more units of VR-N1600U/E to the rack, make sure to mount it at a distance that is at least equivalent to one unit. 10

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32

10
Getting Started
Rear I/O Terminals
Use the supplied rack mount bracket to mount VR-N1600U/E
to the EIA rack.
1
Mount the rack mount bracket using screw (1)
Use the 4 screws (M4 x 10 mm) supplied to fasten
VR-N1600U/E at the two sides.
2
Remove screws
B
of the foot (4 pcs) at the
bottom
Remove the foot.
3
Mount to the rack using screws
C
Use the 4 screws (M5 x 11 mm) supplied to fasten this
unit to the rack.
Note :
Do not place any object on the VR-N1600U/E unit that
has been mounted to the rack. Doing so may cause it to
lose balance and drop or fall, hence resulting in injuries or
damages.
When mounting 2 or more units of VR-N1600U/E to the
rack, make sure to mount it at a distance that is at least
equivalent to one unit.
Part Names and Functions
(continued)
Terminal
Remarks
e
[ALARM
IN]
Memo :
Set the impedance at the output
end to 10k
K
or below.
Make
Contact
Input
f
[EMER-
GENCY]
g
[ALARM
RESET]
Memo :
Set the impedance at the output
end to 10k
K
or below.
Make
Contact
Input
h
[EXT REC
IN]
Memo :
Set the impedance at the output
end to 10k
K
or below.
Make
Contact
Input
j
[OPE ON/
OFF]
Memo :
Set the impedance at the output
end to 10k
K
or below.
Make
Contact
Input
j
[REC
TALLY]
k
[ALARM
OUT]
l
[WARN-
ING OUT]
m
[OPTION
OUT1]
[OPTION
OUT2]
(External Pull-up Level)
The make contact is formed using
the individual output terminals and
the COM terminal. Turning off the
power of VR-N1600U/E switches the
output of the output terminals to
break.
Auto
Collector
Output
(DC15V, 10
mA and
below)
250 ms
and above
250 ms
and above
Make
Break
250 ms
and above
250 ms
and above
1 s and
above
Approx. 50 ms
OPE ON
OPE OFF
Make
Output In
Progress
Break
Output In
Progress
Mounting to a Rack
Rack Mount
Bracket
(4 Locations)