LG 32TNF5J-B Owners Manual - Page 131

Brightness Range Adjustment] Command: s n, ab, n Set ID OK/NGa7 Data1Data2Data3

Page 131 highlights

ENGLISH 108. [USB2 to HDBaseT] (Command: s n, c3) Sets USB2 to HDBaseT. Transmission (s)(n)( )(Set ID)( )(c)(3)( )(Data)(Cr) Data 00: [Off] 01: [On] Acknowledgment (n)( )(Set ID)( )(OK/NG)(c)(3)(Data)(x) * This feature may not be available for all models. 117 111. [Color Calibration] (Command: s n, d6) Selects Colour Calibration. Transmission (s)(n)( )(Set ID)( )(d)(6)( )(Data)(Cr) Data 00: Off 01: On Acknowledgement (n)( )(Set ID)( )(OK/NG)(d)(6)(Data)(x) * It may not be supported depending on the model. 109. [Change Password] (Command: s n, a7) Changes password. Transmission (s)(n)( )(Set ID)( )(a)(7)( )(Data1)(Data2)(Data3) (Data4)(Data5)(Data6)( )(Data7)(Data8)(Data9) (Data10)(Data11)(Data12)(Cr) Data 1~6: 0~9(Previously set password) Data 7~12: 0~9(New password) Acknowledgement (n)( )(Set ID)( )(OK/NG)(a)(7)( )(Data1)(Data2)(Data3) (Data4)(Data5)(Data6)( )(Data7)(Data8)(Data9) (Data10)(Data11)(Data12)(x) * This feature may not be available for all models. 112. [Quiet Mode] (Command: s n, c7) Selects Quiet Mode. Transmission (s)(n)( )(Set ID)( )(c)(7)( )(Data)(Cr) Data 00: Off 01: On Acknowledgement (n)( )(Set ID)( )(OK/NG)(c)(7)(Data)(x) * It may not be supported depending on the model. 110. [Brightness Range Adjustment] (Command: s n, ab) Adjust the brightness range. Transmission (s)(n)( )(Set ID)( )(a)(b)( )(Data1)( )(Data2)(Cr) Data 1 00: Minimum brightness control 01: Maximum brightness control Data 1 00~64: Range control Acknowledgement (n)( )(Set ID)( )(OK/NG)(a)(b)(Data1)(Data2)(x) * This feature may not be available for all models. * Data2 only supports Hex values that are multiples of 5. * The range of minimum brightness value cannot exceed the range of maximum brightness, and the range of maximum brightness value cannot be less than the range of minimum brightness. 113. [Quick Start+] (Command: s n, 0e) Selects Quick Start+ Mode. Transmission (s)(n)( )(Set ID)( )(0)(e)( )(Data)(Cr) Data 00: Off 01: On Acknowledgement (n)( )(Set ID)( )(OK/NG)(0)(e)(Data)(x) * It may not be supported depending on the model.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138

117
ENGLISH
108. [USB2 to HDBaseT] (Command: s n, c3)
Sets USB2 to HDBaseT.
Transmission
(s)(n)( )(Set ID)( )(c)(3)( )(Data)(Cr)
Data
00: [Off]
01: [On]
Acknowledgment
(n)( )(Set ID)( )(OK/NG)(c)(3)(Data)(x)
* This feature may not be available for all models.
109. [Change Password] (Command: s n, a7)
Changes password.
Transmission
(s)(n)( )(Set ID)( )(a)(7)( )(Data1)(Data2)(Data3)
(Data4)(Data5)(Data6)( )(Data7)(Data8)(Data9)
(Data10)(Data11)(Data12)(Cr)
Data
1~6: 0~9(Previously set password)
Data
7~12: 0~9(New password)
Acknowledgement
(n)( )(Set ID)( )(OK/NG)(a)(7)( )(Data1)(Data2)(Data3)
(Data4)(Data5)(Data6)( )(Data7)(Data8)(Data9)
(Data10)(Data11)(Data12)(x)
* This feature may not be available for all models.
110. [Brightness Range Adjustment] (Command: s n, ab)
Adjust the brightness range.
Transmission
(s)(n)( )(Set ID)( )(a)(b)( )(Data1)( )(Data2)(Cr)
Data 1 00: Minimum brightness control
01: Maximum brightness control
Data 1 00~64: Range control
Acknowledgement
(n)( )(Set ID)( )(OK/NG)(a)(b)(Data1)(Data2)(x)
* This feature may not be available for all models.
* Data2 only supports Hex values that are multiples of 5.
* The range of minimum brightness value cannot exceed the
range of maximum brightness, and the range of maximum
brightness value cannot be less than the range of minimum
brightness.
111. [Color Calibration] (Command: s n, d6)
Selects Colour Calibration.
Transmission
(s)(n)( )(Set ID)( )(d)(6)( )(Data)(Cr)
Data
00: Off
01: On
Acknowledgement
(n)( )(Set ID)( )(OK/NG)(d)(6)(Data)(x)
* It may not be supported depending on the model.
112. [Quiet Mode] (Command: s n, c7)
Selects Quiet Mode.
Transmission
(s)(n)( )(Set ID)( )(c)(7)( )(Data)(Cr)
Data
00: Off
01: On
Acknowledgement
(n)( )(Set ID)( )(OK/NG)(c)(7)(Data)(x)
* It may not be supported depending on the model.
113. [Quick Start+] (Command: s n, 0e)
Selects Quick Start+ Mode.
Transmission
(s)(n)( )(Set ID)( )(0)(e)( )(Data)(Cr)
Data
00: Off
01: On
Acknowledgement
(n)( )(Set ID)( )(OK/NG)(0)(e)(Data)(x)