3. TECHNICAL BRIEF 3.4. Power ON/OFF KE600/KE608 Power State : Defined 3cases as follow ] Power-ON : Power key detect ( SM-Power's ON port ] Power-ON-charging : Charger detect. ] Power-ON-remote : remote power on detect (Factory use only) Figure 8 Power on application. Input ON is a power-on input for SM-POWER with 2 active high levels (see Figure 8). It might be triggered by a push button or by the RTCOUT output of the S-GOLD device as well. To detect if the push-button is pressed during system operation the logical level at pin ON or its change (if Bit 1 EION in INTCTRL2 is asserted) is recorded in bit LON of the ISF register. If the high level of voltage at pin ON does not reach VIHdet (Vbat-0.8 ~ Vbat-0.3) the above-mentioned bit won't be set. To support Remote power on function for factory mass production, applied an analog switch as following figure. As monitoring the RPWRON(GPIO_110) and Key matrix KP_OUT(1) & KP_IN(5), KE600/KE608 system recognize whether remote power on or End-key pushed - 39 -