Input Test 1 Mode.
View all LG LBC24360ST manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 32 highlights
8-3 Poor cooling in Fresh food section No Checking flow 1 1-. Unplug connector from CON7. 2-. Check resistance between wires White to White. Result & SVC Action Temperature 23°F °C 32°F °C 41°F °C 50°F °C 59°F °C Result 38 30 24 19.5 16 The sensor is determined by the temperature. For example, 30kΩ indicates 32°F. 2 Reset the unit and Input Test 1 Mode. (Push the button 1 time) 3 Open the fresh food door and Check the air flow. 4 Check the air temperature. Cold or not ? Status Windy No windy SVC Action Go to the 4 Check the F Fan motor Check the damper (Go to the 5) Status Cold Not cold SVC Action Explain to customer Check the Compressor And sealed system 32
8-3 Poor cooling in Fresh food section
No
1
Checking flow
2
Reset the unit and
Input Test 1 Mode.
(Push the button 1 time)
3
Open the fresh food door and Check the
air flow.
The sensor is determined by
the temperature.
For example, 30kω indicates 32°F.
Result & SVC Action
Temperature
23°F
°C
32°F
°C
41°F
°C
50°F
°C
59°F
°C
Result
38
30
24
19.5
16
Status
Windy
No windy
SVC Action
Go to the 4
Check the F Fan motor
Check the damper
(Go to the 5)
4
Check the air temperature.
Cold or not ?
Status
Cold
Not cold
SVC Action
Explain to customer
Check the Compressor
And sealed system
<Swing Model>
<Drawer Model>
1-. Unplug connector from
.
2-. Check resistance between wires
.
CON7
White
to White
32