LG LBC24360ST Service Manual - Page 34
SVC Action
View all LG LBC24360ST manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 34 highlights
No Checking flow 5 Check the Fan motor. Rotate fan using your hand. It feel sticky, change the motor. (cause of ice or rust inside of motor). Result & SVC Action Point Motor Result Sticky SVC Action Change the motor 6 1.- Check for loose connection in CON7. 2-. Check fan motor voltage. Point (1) ~ (2) (1) ~ (3) Result Below 12 V 0 or 5 V SVC Action Change the PCB Change the motor (3) (2) (1) (3)(2)(1) 34
No
Checking flow
5
Check the Fan motor
.
Rotate fan using your hand.
It feel sticky, change the motor.
(cause of ice or rust inside of motor).
6
Result & SVC Action
Below 12 V
0 or 5 V
(1) ~ (2)
(1) ~ (3)
Change the PCB
Change the motor
Point
Result
SVC Action
Sticky
Motor
Change the motor
Point
Result
SVC Action
<CON7>
(3) (2) (1)
<Swing Model>
<Drawer Model>
1.- Check for loose connection in
.
2-. Check fan motor voltage.
CON7
34