LG LBC24360ST Service Manual - Page 39
Component Testing Information - manual
View all LG LBC24360ST manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 39 highlights
10. COMPONENT TESTING INFORMATION 10-1 Defrost Controller Assembly Function - Controller assembly is consist of 2 kinds of part those are fuse-m and sensor. we can decide part is defect or not when we check the resistance. - Fuse-m can cut off the source when defrost heater operate the unusual high temperature. - Sensor give temperature information to Micom How to Measure (Fuse-M) (1) to (2) Set a ohmmeter to the 2 housing pin. Measure the 2 pin connected to Fuse-M. If the ohmmeter indicate below 0.1ohm fuse-m is a good condition, But infinitely great ohm Fuse-M is disconnection How to Measure (Sensor) (1) to (2) Set a ohmmeter to The 2housing pin. Measure the 2 pin connected to Sensor. If the ohmmeter indicate 11㏀ (at room temperature) Sensor is not a defect. When check the ohm at other temperature Check the sensor manual. Standard Fuse-M (at all temperature) Test Point Ressult (1) to (2) 0 ~ 0.1Ω Sensor (at room temperature) Test Point Ressult (1) to (2) 11Ω 39