11-1 CHECK A - There is PC Board located in the PCB case. The control driver is PC board for the compressor. - This step shows the source voltage of the driver PC board. Step1. Open PCB Cover Step2. Check Driver PCB * Driver PCB located in back plate cover behind the refrigerator. LED Lamp IPM Output check - Measure the voltage between the POWER and COMM pins of the connector as shown below. Check to make sure compressor is receiving voltage from IPM Multi Tester A-Inverter - In order to determine whether the compressor is operating normally, check the output voltage during the refrigeration cycle. - After initial power-up, when the compressor begins to operate, wait 10 minutes before checking. - The compressor is operating normally if the voltage is greater than 80V. 44

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69

11-1 CHECK A
-
There is PC Board located in the PCB case.
The control driver is PC board for the compressor.
-
This step shows the source voltage of the driver PC board.
*
Driver PCB located in back plate cover
behind the refrigerator.
Step1. Open PCB Cover
Step2. Check Driver PCB
LED Lamp
-
Measure the voltage between the POWER and COMM pins of the connector as shown below.
Check to make sure compressor is receiving voltage from IPM
-
In order to determine whether the compressor is operating normally,
check the output voltage during the refrigeration cycle.
-
After initial power-up, when the compressor begins to operate, wait 10
minutes before checking.
-
The compressor is operating normally if the voltage is greater than 80V.
IPM Output check
A-Inverter
Multi
Tester