RS-232C Configurations, Set ID, Wire Configuration, Serial female-female NULL modem cable
View all LG M2280D-PU manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 121 highlights
RS-232C Configurations Either cable below can be used. 7-Wire Configuration (Serial female-female NULL modem cable) PC SET RXD 2 3 TXD TXD 3 2 RXD GND 5 5 GND DTR 4 6 DSR DSR 6 4 DTR RTS 7 8 CTS CTS 8 7 RTS D-Sub 9 D-Sub 9 RXD TXD GND DTR DSR RTS CTS 3-Wire Configurations (Not standard) PC SET 2 3 TXD 3 2 RXD 5 5 GND 4 6 DTR 6 4 DSR 7 7 RTS 8 8 CTS D-Sub 9 D-Sub 9 Set ID Use this function to specify a set ID number. Refer to 'Real Data Mapping'. OPTION Menu Language Audio Language Input Label Key Lock Caption Set ID Power Indicator Demo Mode Move Enter : English : English : Off : Off : O1 ff ꔋ : On : Off v ➩ OPTION Move Enter Menu Language : English Audio Language : English Input Label Key Lock : Off Caption Set ID : Off : 1Off ◄ 1 ► ꔋ Power Indicator : On Demo Mode : Off Close v 1 MENU 2 3 Select OPTION. * Real data mapping 1 : Step 0 Select Set ID. Choose the desired TV ID number.. The adjustment range of Set ID is 1 to 99. A : Step 10 (Set ID 10) F : Step 15 (Set ID 15) 10 : Step 16 (Set ID 16) 63 : Step 99 (Set ID 99) 64 : Step 100 • Press MENU or EXIT to close the menu window. • Press BACK to move to the previous menu screaen. APPENDIX 121