LG WKEX200HWA Owners Manual - Page 16

Four-Wire Direct Wire

Page 16 highlights

16 INSTALLATION bc b e a d a White Wire moved from Ground Screw b Hot Leads of Power Cord (Black and Red) c Neutral Wire (White) d Power Cord Ground Wire e Ground Screw (green) Four-Wire Direct Wire • A UL-listed strain relief is required. • Use UL-listed 4-wire #10 AWG minimum copper conductor cable. Allow at least 5 ft. (1.5 m) of wire to allow for removal and reinstallation of the dryer. 1 Remove 5 inches (12.7 cm) of the outer covering from the wire and remove 5 inches of insulation from the ground wire. Cut off approximately 1.5 inches (3.8 cm) from the other three wires and strip 1 inch (2.5 cm) insulation from each wire. Bend the ends of the three shorter wires into a hook shape. 1'' (2.5 cm) a 5'' (12.7 cm) a Ground Wire 2 Remove the terminal block access cover on the upper back of the appliance. 3 Install UL-listed strain relief into the power cord through-hole. 4 Thread the 4-wire #10 AWG minimum copper power cable prepared in step 1 through the strain relief. a b c a Terminal Block b UL-Listed Strain Relief c UL-Listed 4-Wire Power Cord 5 Transfer the appliance's ground wire from behind the green ground screw to the center of the terminal block. 6 Attach the two hot leads (black and red) of the power cord to the outer terminal block screws. 7 Attach the neutral (white) wire to the center screw of the terminal block. 8 Attach the power cord ground wire to the green ground screw. 9 Tighten all screws securely. 10 Reinstall the terminal block access cover. bc b e a d a White Wire moved from Ground Screw b Hot Leads of Power Cord (Black and Red) c Neutral Wire (White) d Power Cord Ground Wire e Ground Screw (green)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172
  • 173
  • 174
  • 175
  • 176
  • 177
  • 178
  • 179
  • 180
  • 181
  • 182
  • 183
  • 184
  • 185
  • 186
  • 187
  • 188
  • 189
  • 190
  • 191
  • 192
  • 193
  • 194
  • 195

16
INSTALLATION
a
White Wire moved from Ground Screw
b
Hot Leads of Power Cord (Black and Red)
c
Neutral Wire (White)
d
Power Cord Ground Wire
e
Ground Screw (green)
Four-Wire Direct Wire
1
Remove 5 inches (12.7 cm) of the outer
covering from the wire and remove 5 inches
of insulation from the ground wire. Cut off
approximately 1.5 inches (3.8 cm) from the
other three wires and strip 1 inch (2.5 cm)
insulation from each wire. Bend the ends of
the three shorter wires into a hook shape.
a
Ground Wire
2
Remove the terminal block access cover on
the upper back of the appliance.
3
Install UL-listed strain relief into the power
cord through-hole.
4
Thread the 4-wire #10 AWG minimum copper
power cable prepared in step 1 through the
strain relief.
a
Terminal Block
b
UL-Listed Strain Relief
c
UL-Listed 4-Wire Power Cord
5
Transfer the appliance's ground wire from
behind the green ground screw to the center
of the terminal block.
6
Attach the two hot leads (black and red) of the
power cord to the outer terminal block
screws.
7
Attach the neutral (white) wire to the center
screw of the terminal block.
8
Attach the power cord ground wire to the
green ground screw.
9
Tighten all screws securely.
10
Reinstall the terminal block access cover.
a
White Wire moved from Ground Screw
b
Hot Leads of Power Cord (Black and Red)
c
Neutral Wire (White)
d
Power Cord Ground Wire
e
Ground Screw (green)
A UL-listed strain relief is
required.
Use UL-listed 4-wire #10 AWG minimum
copper conductor cable. Allow at least 5 ft. (1.5
m) of wire to allow for removal and
reinstallation of the dryer.
a
b
b
c
d
e
5’’ (12.7 cm)
1’’ (2.5 cm)
a
a
b
c
a
b
b
c
d
e