Page 33 highlights

4227-300 Print quality problems Symptom No print, but carrier moves as if printing. Print density is light. Uneven print density across the print line Specific dots missing. Scattered ink, smearing, blurred characters Fuzzy print Action Be sure the printhead cables are not loose or damaged. Be sure the interface cable is connected properly. Check the ribbon cartridge for binds or damage. Go to the "Print wire drive failure service check" on page 2-28. If the ribbon has reached its end of life or is worn, the ribbon cartridge needs to be replaced. Go to the "Auto Gap service check" on page 2-11. If no problem is found, go to the"Ribbon drive service check" on page 2-30. Be sure the printhead cables are connected correctly to the printhead and the sub logic board. Clean the printhead. Set the Auto Gap to On in the user menus and run the print test. If the print is light at one edge and uniformly gets darker across the page to the other edge, perform the "Printhead-to-platen gap adjustment" on page 4-2. Go to the "Print wire drive failure service check" on page 2-28. Clean the printhead nose. Clean the ribbon guide and shield. If the ribbon has reached its end of life or is worn, the ribbon cartridge needs to be replaced. Go to the "Print quality service check" on page 2-27. Diagnostic information 2-9

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146

Diagnostic information
2-9
4227-300
Print quality problems
Symptom
Action
No print, but carrier
moves as if printing.
Be sure the printhead cables are not loose or
damaged.
Be sure the interface cable is connected properly.
Check the ribbon cartridge for binds or damage.
Go to the
“Print wire drive failure service
check” on page 2-28
.
Print density is light.
If the ribbon has reached its end of life or is worn,
the ribbon cartridge needs to be replaced.
Go to the
“Auto Gap service check” on page
2-11
. If no problem is found, go to the
“Ribbon
drive service check” on page 2-30
.
Uneven print density
across the print line
Specific dots
missing.
Be sure the printhead cables are connected
correctly to the printhead and the sub logic board.
Clean the printhead.
Set the Auto Gap to
On
in the user menus and run
the print test. If the print is light at one edge and
uniformly gets darker across the page to the other
edge, perform the
“Printhead-to-platen gap
adjustment” on page 4-2
.
Go to the
“Print wire drive failure service
check” on page 2-28
.
Scattered ink,
smearing, blurred
characters
Fuzzy print
Clean the printhead nose.
Clean the ribbon guide and shield.
If the ribbon has reached its end of life or is worn,
the ribbon cartridge needs to be replaced.
Go to the
“Print quality service check” on page
2-27
.