Lexmark 4227 Service Manual - Page 44

Operator panel service check, Start/Stop, Load/Unload, FormFeed., Operator Panel Disabled, Micro

Page 44 highlights

4227-300 Operator panel service check Note: Press any button except Start/Stop, Load/Unload, or FormFeed. If Operator Panel Disabled is displayed, unlock the operator panel by powering up with the Micro↑ and Micro↓keys pressed. Use the same procedure to re-lock the panel after service is complete. FRU Action 1 Operator Panel If there is a 631 Display RAM Error, replace the operator panel. If there is a 63B Key Scan Error, one or more buttons are being detected as pressed during power-up. 2 Printer Cable Operator Panel Replace the operator panel. During power-up, all LEDs and all LCD pels should turn on briefly. Enter the Service Menu and perform the Button Test. If there are missing or extra pels displayed, or if any of these tests fail, check the condition and continuity of the operator panel cable. 3 Cover Switch Replace the cable or the operator panel. If Cover Open is displayed, check the cover switch. Jumper the cover switch connector on the operator panel. If Cover Open is displayed, check the condition and continuity of the operator panel cable. Replace the cable or the operator panel. 4 Main Logic Board If the symptom has not changed, replace the main logic board. 2-20 Service Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146

2-20
Service Manual
4227-300
Operator panel service check
Note:
Press any button except
Start/Stop
,
Load/Unload,
or
FormFeed.
If
Operator Panel Disabled
is displayed, unlock the
operator panel by powering up with the
Micro
and
Micro
keys
pressed. Use the same procedure to re-lock the panel after service
is complete.
FRU
Action
1
Operator Panel
If there is a 631 Display RAM Error, replace the
operator panel.
If there is a 63B Key Scan Error, one or more
buttons are being detected as pressed during
power-up.
Replace the operator panel.
2
Printer Cable
Operator Panel
During power-up, all LEDs and all LCD pels
should turn on briefly.
Enter the Service Menu and perform the
Button Test. If there are missing or extra pels
displayed, or if any of these tests fail, check the
condition and continuity of the operator panel
cable.
Replace the cable or the operator panel.
3
Cover Switch
If
Cover Open
is displayed, check the cover
switch.
Jumper the cover switch connector on the
operator panel. If
Cover Open
is displayed,
check the condition and continuity of the
operator panel cable. Replace the cable or the
operator panel.
4
Main Logic Board
If the symptom has not changed, replace the
main logic board.