WIRE ACCESSORIES TO EXPANSION BOARD, Photoelectric Sensors and Edge Sensors, Control Station

Page 32 highlights

WIRE ACCESSORIES TO EXPANSION BOARD Photoelectric Sensors and Edge Sensors The EYES/EDGE terminals are used for connecting entrapment protection devices. At least two external monitored entrapment protection devices are required prior to gate movement; one in the open and one in the closed direction. Monitored entrapment protection devices should have been installed with the operator at the time of installation. Only ONE monitored device may be connected to each input. A monitored device sends a pulsed signal to the operator so the operator is aware of the device. If the operator does not receive the signal from the device indicating it is working properly, it will not run in that direction. TERMINALS FUNCTION EYE ONLY and COM Open or Close Direction Photoelectric Sensors, the functionality is based on the switch settings (located next to the terminals) WIRING EXAMPLE Switch set to CLOSE: gate reverses fully when an obstruction is sensed Switch set to OPEN: gate reverses 4 seconds when an obstruction is sensed EYE/EDGE and COM EYE/EDGE and COM Open or Close Direction Photoelectric Sensors or Edge Sensor, the functionality is based on the switch settings (located next to the terminals) Switch set to CLOSE: gate reverses fully when an obstruction is sensed Switch set to OPEN: gate reverses 4 seconds when an obstruction is sensed Open or Close Direction Photoelectric Sensors or Edge Sensor, the functionality is based on the switch settings (located next to the terminals) Switch set to CLOSE: gate reverses fully when an obstruction is sensed Switch set to OPEN: gate reverses 4 seconds when an obstruction is sensed Control Station TERMINALS SBC and COM OPEN and COM CLOSE and COM STOP and COM FUNCTION l Gate command sequence - Open, Stop, Close, Stop, ... l Soft Open, Soft Close, Soft Stop (maintained switch does not override external safeties and does not reset alarm condition) l Open command - opens a closed gate l Soft open (maintained switch does not override external safeties and does not reset alarm condition) l If maintained, pauses Timer-to-Close at OPEN limit l Opens a closing gate and holds open an open gate l Close command - closes an open gate l Soft close (maintained switch does not override external safeties and does not reset alarm condition) l Stop command - stops a moving gate l If maintained, pauses Timer-to-Close at OPEN limit l Overrides an Open or Close command WIRING EXAMPLE 32

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

32
Photoelectric Sensors and Edge Sensors
The EYES/EDGE terminals are used for connecting entrapment protection devices.
At least two external monitored entrapment protection devices are
required prior to gate movement;
one in the open and one in the closed direction. Monitored entrapment protection devices should have been installed
with the operator at the time of installation. Only ONE monitored device may be connected to each input. A monitored device sends a pulsed signal to the
operator so the operator is aware of the device. If the operator does not receive the signal from the device indicating it is working properly, it will not run in
that direction.
TERMINALS
FUNCTION
WIRING EXAMPLE
EYE ONLY and COM
Open or Close Direction Photoelectric Sensors, the functionality is
based on the switch settings (located next to the terminals)
Switch set to CLOSE:
gate reverses fully when an obstruction is
sensed
Switch set to OPEN:
gate reverses 4 seconds when an obstruction
is sensed
EYE/EDGE and COM
Open or Close Direction Photoelectric Sensors or Edge Sensor, the
functionality is based on the switch settings (located next to the
terminals)
Switch set to CLOSE:
gate reverses fully when an obstruction is
sensed
Switch set to OPEN:
gate reverses 4 seconds when an obstruction
is sensed
EYE/EDGE and COM
Open or Close Direction Photoelectric Sensors or Edge Sensor, the
functionality is based on the switch settings (located next to the
terminals)
Switch set to CLOSE:
gate reverses fully when an obstruction is
sensed
Switch set to OPEN:
gate reverses 4 seconds when an obstruction
is sensed
Control Station
TERMINALS
FUNCTION
WIRING EXAMPLE
SBC and COM
l
Gate command sequence - Open, Stop, Close, Stop, ...
l
Soft Open, Soft Close, Soft Stop (maintained switch does not
override external safeties and does not reset alarm condition)
OPEN and COM
l
Open command - opens a closed gate
l
Soft open (maintained switch does not override external safeties
and does not reset alarm condition)
l
If maintained, pauses Timer-to-Close at OPEN limit
l
Opens a closing gate and holds open an open gate
CLOSE and COM
l
Close command - closes an open gate
l
Soft close (maintained switch does not override external safeties
and does not reset alarm condition)
STOP and COM
l
Stop command - stops a moving gate
l
If maintained, pauses Timer-to-Close at OPEN limit
l
Overrides an Open or Close command