LiftMaster SL585UL Installation Manual - Page 7
Operator Specifications, External Entrapment Protection Device Inputs non-contact - model
View all LiftMaster SL585UL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 7 highlights
INTRODUCTION Operator Specifications Usage Classification Class I, II, III, & IV Accessory Power Main Control Board: 24 Vdc, 500 mA max. Terminal Strip: 24 Vac, 2.2 A max. for 120/208-240 Vac, Single Phase and 208-240/480 Vac, Three Phase 24 Vac, 1.3 A max. for 575 Vac, Three Phase Maximum Gate Weight 1/2 HP (1 Phase and 3 Phase): 1000 lbs. 1 HP (1 Phase and 3 Phase): 1600 lbs. 1-1/2 HP (1 Phase): 1900 lbs. Minimum Gate Travel Distance 4 feet (1.2 m) Maximum Gate Travel Distance 1/2 HP (1 Phase and 3 Phase): Cantilever - 25 feet, OH Roller - 45 feet, V-Track - 35 feet 1 HP (1 Phase and 3 Phase): Cantilever - 35 feet, OH Roller - 70 feet, V-Track - 50 feet 1-1/2 HP (1 Phase): Cantilever - 40 feet, OH Roller - 75 feet, V-Track - 55 feet Maximum Gate Travel Speed 1 foot/second Maximum Daily Cycle Rate Continuous Maximum Duty Cycle Continuous Operating Temperature Without Heater: -20°C to 60°C (-4°F to 140°F) With Optional Heater: -40°C to 60°C (-40°F to 140°F) Expansion Board Provided External Entrapment Protection Device Inputs (non-contact Main board - up to 2 close entrapment protection devices and 1 open entrapment and/or contact) protection device. Expansion board - up to 3 entrapment protection devices configurable to either close or open and up to 4 edge sensors using wireless edge sensor kit model LMWEKITU . 7