LiftMaster SL585UL Installation Manual - Page 36

LiftMaster Internet Gateway (Not Provided), Erase All Codes

Page 36 highlights

PROGRAMMING LiftMaster Internet Gateway (Not Provided) To program the operator to the LiftMaster Internet Gateway: Program using the learn button on the operator's control board: Program using the reset button on the operator: 1. Connect the ethernet cable to the LiftMaster Internet Gateway and the router. 2. Connect power to the LiftMaster Internet Gateway. 3. Create an online account by visiting www.myliftmaster.com. 4. Register the LiftMaster Internet Gateway. 5. Use an internet enabled computer or smartphone to add devices. The LiftMaster Internet Gateway will stay in learn mode for three minutes. 6. Press the Learn button twice on the primary operator (the operator will beep as it enters learn mode). The LiftMaster Internet Gateway will pair to the operator if it is within range and the operator will beep if programming is successful. 1. Connect the ethernet cable to the LiftMaster Internet Gateway and the router. 2. Connect power to the LiftMaster Internet Gateway. 3. Create an online account by visiting www.myliftmaster.com. 4. Register the LiftMaster Internet Gateway. 5. Use an internet enabled computer or smartphone to add devices. The LiftMaster Internet Gateway will stay in learn mode for three minutes. 6. Ensure gate is closed. 7. Give the operator an OPEN command. 8. Within 30 seconds, when the gate is at the open limit press and release the reset button 3 times (on primary gate) to put primary operator into High Band Learn Mode (the operator will beep as it enters learn mode). The LiftMaster Internet Gateway will pair to the operator if it is The status as shown by the LiftMaster Internet Gateway app will be either "open" or "closed". The gate operator can then be controlled through the LiftMaster Internet Gateway app. Erase All Codes 1. Press and release the LEARN button (operator will beep and green XMITTER LED will light). 2. Press and hold the LEARN button again until the green XMITTER LED flashes and then release the button (approximately 6 seconds). All remote control codes are now erased. To Remove and Erase Monitored Entrapment Protection Devices 1. Remove the entrapment protection device wires from the terminal block. 2. Press and release the OPEN LEFT and OPEN RIGHT buttons simultaneously. The handing direction LED will remain solid. The other direction LED will begin flashing (entering setup mode). 3. Press the OPEN LEFT and OPEN RIGHT buttons simultaneously to exit. Constant Pressure Override (CPO) Constant Pressure Override is for use with KPW5 and KPW250 keypads (not provided). The KPW5/KPW250 wireless commercial keypads are security keypads and can only be programmed to ONE gate operator (see the KPW5/KPW250 manual for complete programming instructions). The Constant Pressure Override feature is intended to temporarily override a fault in the entrapment protection system, in order to operate the gate until the external entrapment protection device is realigned or repaired. Use the feature only in line of sight of the gate when no obstructions to travel are present. External entrapment protection devices include LiftMaster monitored photoelectric sensors and LiftMaster monitored wired and wireless edge sensors. Be sure to repair or replace these devices promptly if they are not working properly. To use Constant Pressure Override: 1. Enter a valid 4-digit PIN. 2. Press and hold # for 5 seconds to enter CPO. Continue to hold # to keep the operator in motion. A continuous tone will sound until limit is met and/or # is released. 3. The operator will stop when either the operator reaches a limit or the user releases #. 36

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

36
LiftMaster Internet Gateway (Not Provided)
To program the operator to the LiftMaster Internet Gateway:
Program using the learn button on the operator's control board:
Program using the reset button on the operator:
1.
Connect the ethernet cable to the LiftMaster Internet Gateway and the
router.
2.
Connect power to the LiftMaster Internet Gateway.
3.
Create an online account by visiting www.myliftmaster.com.
4.
Register the LiftMaster Internet Gateway.
5.
Use an internet enabled computer or smartphone to add devices. The
LiftMaster Internet Gateway will stay in learn mode for three minutes.
6.
Press the Learn button twice on the primary operator (the operator
will beep as it enters learn mode). The LiftMaster Internet Gateway will
pair to the operator if it is within range and the operator will beep if
programming is successful.
1.
Connect the ethernet cable to the LiftMaster Internet Gateway and the
router.
2.
Connect power to the LiftMaster Internet Gateway.
3.
Create an online account by visiting www.myliftmaster.com.
4.
Register the LiftMaster Internet Gateway.
5.
Use an internet enabled computer or smartphone to add devices. The
LiftMaster Internet Gateway will stay in learn mode for three minutes.
6.
Ensure gate is closed.
7.
Give the operator an OPEN command.
8.
Within 30 seconds, when the gate is at the open limit press and
release the reset button 3 times (on primary gate) to put primary
operator into High Band Learn Mode (the operator will beep as it
enters learn mode). The LiftMaster Internet Gateway will pair to the
operator if it is
The status as shown by the LiftMaster Internet Gateway app will be either “open” or “closed”. The gate operator can then be controlled through the
LiftMaster Internet Gateway app.
Erase All Codes
1.
Press and release the LEARN button (operator will beep and green XMITTER LED will light).
2.
Press and hold the LEARN button again until the green XMITTER LED flashes and then release the button (approximately 6 seconds). All remote
control codes are now erased.
To Remove and Erase Monitored Entrapment Protection Devices
1.
Remove the entrapment protection device wires from the terminal block.
2.
Press and release the OPEN LEFT and OPEN RIGHT buttons simultaneously. The handing direction LED will remain solid. The other direction LED will
begin flashing (entering setup mode).
3.
Press the OPEN LEFT and OPEN RIGHT buttons simultaneously to exit.
Constant Pressure Override (CPO)
Constant Pressure Override is for use with KPW5 and KPW250 keypads (not provided). The KPW5/KPW250 wireless commercial keypads are security
keypads and can only be programmed to ONE gate operator (see the KPW5/KPW250 manual for complete programming instructions).
The Constant Pressure Override feature is intended to temporarily override a fault in the entrapment protection system, in order to operate the gate until the
external entrapment protection device is realigned or repaired. Use the feature only in line of sight of the gate when no obstructions to travel are present.
External entrapment protection devices include LiftMaster monitored photoelectric sensors and LiftMaster monitored wired and wireless edge sensors. Be
sure to repair or replace these devices promptly if they are not working properly.
To use Constant Pressure Override:
1.
Enter a valid 4-digit PIN.
2.
Press and hold # for 5 seconds to enter CPO. Continue to hold # to keep the operator in motion. A continuous tone will sound until limit is met and/or
# is released.
3.
The operator will stop when either the operator reaches a limit or the user releases #.