LiftMaster SL585UL Installation Manual - Page 42

Meaning, Solution, Saved, CLOSE EYE/INTERRUPT triggered, causing

Page 42 highlights

TROUBLESHOOTING Code 70 71 72 73 74 75 80 81 82 83 84 91 93 95 96 99 Meaning CLOSE EYE/INTERRUPT triggered, causing reversal, preventing close, or resetting TTC CLOSE EDGE triggered, causing reversal, NO preventing close, or canceling TTC OPEN EYE/EDGE triggered, causing reversal or preventing opening CLOSE EYE/INTERRUPT triggered, causing reversal, preventing close, or resetting TTC CLOSE EYE/EDGE triggered, causing reversal and preventing close or canceling TTC OPEN EYE/EDGE triggered, causing reversal or preventing opening Close input (EYE/EDGE) communication fault from other operator Open input (EYE/EDGE) communication fault from other operator Close input (EYE/EDGE) communication fault (expansion board) Open input (EYE/EDGE) communication fault (expansion board) Non-monitored device detected on the wireless safety system Force Reversal (Operator 1) RPM / STALL Reversal (Operator 1) AC motor no start condition Current Sensor Fault Normal Operation Solution IF an obstruction occurred, no action required. If an obstruction did NOT occur, check alignment, inputs, and wiring on main control board IF an obstruction occurred, no action required. If an obstruction did NOT occur, check alignment, inputs, and wiring on expansion board. Check inputs and communication method between operators, either wired bus or radio. Ensure operator is powered. May have to erase the wireless communication and reprogram the two operators. Check the connections between the main board and the expansion board. Non-monitored contact closure devices are not supported. Make sure connected devices are monitored. Check edges for proper orientation and resistive end cap connection. Check for obstruction. If no obstruction, check that the mechanical assembly is engaged and free to move. See section on Limit and Force Adjustment, and Obstruction Test. Check for obstruction. If no obstruction, check the operator wiring and that the mechanical assembly is engaged and free to move. Replace APE assembly. Motor start sequence failed. If the gate and motor are NOT moving, or moving too slow, check for an obstructed gate, binding in the mechanism, and relay board and start capacitor connections. If the gate and motor ARE moving, failure is due to loss of the encoder signal. Check the encoder cup and sensor on the limit shaft, and wiring. A fault was detected on the current sensor. Make sure the current sensor is connected to the main control board. Check the current sensor harness for an open or short. The operator will need a power cycle to resume operation after correcting the fault. If the fault continues, replace the power board. No action required Saved NO NO YES YES YES YES YES YES YES YES 42

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

42
Code
Meaning
Solution
Saved
70
CLOSE EYE/INTERRUPT triggered, causing
reversal, preventing close, or resetting TTC
IF an obstruction occurred, no action required. If an obstruction did NOT
occur, check alignment, inputs, and wiring on main control board
NO
71
CLOSE EDGE triggered, causing reversal, NO
preventing close, or canceling TTC
72
OPEN EYE/EDGE triggered, causing reversal or
preventing opening
73
CLOSE EYE/INTERRUPT triggered, causing
reversal, preventing close, or resetting TTC
IF an obstruction occurred, no action required. If an obstruction did NOT
occur, check alignment, inputs, and wiring on expansion board.
NO
74
CLOSE EYE/EDGE triggered, causing reversal and
preventing close or canceling TTC
75
OPEN EYE/EDGE triggered, causing reversal or
preventing opening
80
Close input (EYE/EDGE) communication fault from
other operator
Check inputs and communication method between operators, either wired
bus or radio. Ensure operator is powered. May have to erase the wireless
communication and reprogram the two operators.
YES
81
Open input (EYE/EDGE) communication fault from
other operator
82
Close input (EYE/EDGE) communication fault
(expansion board)
Check the connections between the main board and the expansion board.
YES
83
Open input (EYE/EDGE) communication fault
(expansion board)
84
Non-monitored device detected on the wireless
safety system
Non-monitored contact closure devices are not supported. Make sure
connected devices are monitored. Check edges for proper orientation and
resistive end cap connection.
YES
91
Force Reversal (Operator 1)
Check for obstruction. If no obstruction, check that the mechanical
assembly is engaged and free to move. See section on Limit and Force
Adjustment, and Obstruction Test.
YES
93
RPM / STALL Reversal (Operator 1)
Check for obstruction. If no obstruction, check the operator wiring and
that the mechanical assembly is engaged and free to move. Replace APE
assembly.
YES
95
AC motor no start condition
Motor start sequence failed. If the gate and motor are NOT moving, or
moving too slow, check for an obstructed gate, binding in the mechanism,
and relay board and start capacitor connections. If the gate and motor ARE
moving, failure is due to loss of the encoder signal. Check the encoder
cup and sensor on the limit shaft, and wiring.
YES
96
Current Sensor Fault
A fault was detected on the current sensor. Make sure the current sensor is
connected to the main control board. Check the current sensor harness for
an open or short. The operator will need a power cycle to resume
operation after correcting the fault. If the fault continues, replace the power
board.
YES
99
Normal Operation
No action required
YES
TROUBLESHOOTING