- Linksys SGE2000 | Cisco RPS1000 380W Redundant Power Supply Administration Guide - Page 1
LINKSYS BUSINESS SERIES RPS1000 INSTALLATION AND ADMINISTRATION GUIDE ¸ Linksys One Business Series RPS1000 Installation and Administration Guide March 2007 Linksys One Business Series 380W Redundant Power Supply Model RPS1000 - Linksys SGE2000 | Cisco RPS1000 380W Redundant Power Supply Administration Guide - Page 2
, Inc. Specifications are subject to change without notice. Linksys, the Cisco Systems logo, the Linksys Logo, and the Linksys One logo are registered trademarks of Cisco Systems, Inc. All other trademarks mentioned in this document are the property of their respective owners. Document Revision - Linksys SGE2000 | Cisco RPS1000 380W Redundant Power Supply Administration Guide - Page 3
Power Supply Unit Installation Guide Installation 15 Tools and Equipment Required 15 Attaching the Brackets to the RPS1000 16 Mounting the RPS1000 in a Rack 17 Connecting the RPS1000 17 Appendix A: Technical Specifications 20 Appendix B: Troubleshooting 22 Appendix C: Linksys - Linksys SGE2000 | Cisco RPS1000 380W Redundant Power Supply Administration Guide - Page 4
explains how to install the RPS1000, and provides troubleshooting information. The RPS1000 provides redundant power for the Linksys Business Series family of Ethernet switches. To determine if your switch can use the RPS1000, refer to your switch's documentation. Organization This guide is organized - Linksys SGE2000 | Cisco RPS1000 380W Redundant Power Supply Administration Guide - Page 5
1 • SGE2000 Gigabit Ethernet Switch Quick Installation Guide • SGE2000P Gigabit Ethernet Switch Quick Installation Guide • SFE2000/SFE2000P Fast Ethernet Administration Guide • SFE2000/SFE2000P Fast Ethernet Reference Guide • SGE2000/SGE2000P Gigabit Ethernet Administration Guide • SGE2000/SGE2000P - Linksys SGE2000 | Cisco RPS1000 380W Redundant Power Supply Administration Guide - Page 6
against losses of power due to external power outages. We recommend using an uninterruptable power system (UPS) as protection against power outages. The RPS1000 was designed to support specific Linksys Business Series products. Connectors are not interchangeable. Consult your switch documentation to - Linksys SGE2000 | Cisco RPS1000 380W Redundant Power Supply Administration Guide - Page 7
over capability to ensure that the switch does not reboot if the internal switch power supply should fail • Support for the SFE2000/2000P and SGE2000/2000P Ethernet switches • Small form-factor suitable for rack-mounting to provide maximum wiring closet port density • Two output levels: - -48 VDC - Linksys SGE2000 | Cisco RPS1000 380W Redundant Power Supply Administration Guide - Page 8
use to connect to supported devices. The output LEDs are numbered 1 to 6, which corresponds to the numbers on the DC outputs. LED STBY/ ACTIVE DC TEMP Off Green Amber The RPS1000 is not powered up. The RPS1000 is in active mode and available to backup a failed device. (Blinking) The RPS1000 - Linksys SGE2000 | Cisco RPS1000 380W Redundant Power Supply Administration Guide - Page 9
Chapter RPS1000-Business Series 380W RPS Unit Installation & Administration 2 LED Off Green FAN The The fan is RPS1000 is running. not powered up. STBY/ACTIVE Button Amber The fan is not operating properly. Color Off Green Blinking green Blinking amber Amber DC Output Status No device - Linksys SGE2000 | Cisco RPS1000 380W Redundant Power Supply Administration Guide - Page 10
3 1 AC input connector 2 DC output connectors 3 Fan exhaust Use the supplied AC power cord to connect to an AC power outlet. The DC output connectors require a Cisco 16-pin-to-14-pin cable (RPSCBL1) to connect to supported devices. (One cable is supplied with the RPS1000; you can order additional - Linksys SGE2000 | Cisco RPS1000 380W Redundant Power Supply Administration Guide - Page 11
would typically use one RPS1000 to support one to six switches as shown below. Ethernet Switches 181531 DC output 6 RPS 1000 DC output 1 In this configuration, if one device has a power-supply or power-related failure, the RPS1000 immediately begins to supply power to this device and is no - Linksys SGE2000 | Cisco RPS1000 380W Redundant Power Supply Administration Guide - Page 12
Installation & Administration 2 When the network supports mission-critical applications that require one-to-one redundancy, an RPS1000 is connected to each supported device to ensure that each switch is always supported. This one-to-one redundant configuration is shown below. Ethernet Switches - Linksys SGE2000 | Cisco RPS1000 380W Redundant Power Supply Administration Guide - Page 13
-Business Series 380W RPS Unit Installation & Administration 3 Installation This chapter describes how to install and connect the RPS1000 and includes these topics: • Preparing for Installation • Installing the Switch • Connecting the RPS1000 Preparing for Installation Read these sections and - Linksys SGE2000 | Cisco RPS1000 380W Redundant Power Supply Administration Guide - Page 14
the back of the switch. WARNING: Do not work on the system or connect or disconnect cables during periods of lightning activity. WARNING: Read the installation instructions before connecting the system to the power source. WARNING: To prevent bodily injury when mounting or servicing this unit in - Linksys SGE2000 | Cisco RPS1000 380W Redundant Power Supply Administration Guide - Page 15
all national laws and regulations. WARNING: No user-serviceable parts inside. Do not open. WARNING: Installation of the equipment must comply with local and conditions exist. • Never assume that power is disconnected from a circuit. Always check. Chapter 3: Installation 12 Preparing for - Linksys SGE2000 | Cisco RPS1000 380W Redundant Power Supply Administration Guide - Page 16
your Cisco representative or reseller for support. Replace all packing material into the shipping container and save it. These items are shipped: • The RPS1000 • This Linksys Business Series RPS1000 Redundant Power System Hardware Installation Guide • Product Registration Card • AC power cord - Linksys SGE2000 | Cisco RPS1000 380W Redundant Power Supply Administration Guide - Page 17
, see the Appendix C, "Linksys Contact Information," section. Rack-Mounting To install the chassis in a 19-inch or 24-inch rack, follow the instructions described in these procedures. NOTE: A 24-inch rack requires optional mounting hardware. Chapter 3: Installation 14 Installing the Switch - Linksys SGE2000 | Cisco RPS1000 380W Redundant Power Supply Administration Guide - Page 18
in the rack, which you can determine by experimenting with different configurations. • When equipment installed in a rack (particularly in an enclosed rack) fails, try this test: Operate the equipment by itself, if possible. Power off other equipment in the rack and in adjacent racks to allow - Linksys SGE2000 | Cisco RPS1000 380W Redundant Power Supply Administration Guide - Page 19
rack, an optional bracket kit that is not included with the switch is required. You can order a kit that contains the 24-inch rack-mounting brackets and hardware from Cisco (part number RCKMNT-1RU=). You can install the RPS1000 into a rack with either the front panel or the rear panel facing forward - Linksys SGE2000 | Cisco RPS1000 380W Redundant Power Supply Administration Guide - Page 20
connect the RPS1000 to the AC power, the RPS1000 automatically becomes active. NOTE: Do not use different power sources to power up the RPS1000 and the connected device. If you connect to separate AC power sources, reset conditions might occur. Chapter 3: Installation 17 Connecting the RPS1000 - Linksys SGE2000 | Cisco RPS1000 380W Redundant Power Supply Administration Guide - Page 21
: Attach only the Cisco RPS1000 (model PWR675-AC-RPS-N1) to the RPS1000 receptacle. 3. Connect the other end of the RPS1000 connector cable to the RPS1000 receptacle on the switch. 4. Repeat 2. through 3. for each switch that the RPS1000 will support. Chapter 3: Installation 18 Connecting the - Linksys SGE2000 | Cisco RPS1000 380W Redundant Power Supply Administration Guide - Page 22
Series 380W RPS Unit Installation & Administration 3 5. Connect all supported devices to an AC power source. NOTE: The RPS1000 is designed to provide backup for internal power supply failures of connected device power supplies. It is not designed to act as a backup power source that protects - Linksys SGE2000 | Cisco RPS1000 380W Redundant Power Supply Administration Guide - Page 23
RPS1000-Business Series 380W RPS Unit Installation & Administration A Technical Specifications The 6 to 10 A, 50 to 60 Hz 875 W Power delivery (available 375 W per -48 VDC output and power) Total 300 W per 12 VDC output Standby power 25 W KVA 0.875 KVA Physical Dimensions Weight 11.5 - Linksys SGE2000 | Cisco RPS1000 380W Redundant Power Supply Administration Guide - Page 24
AS/NZS 3260, TS001 CE CCC approval pending CLEI code NOM Appendix RPS1000-Business Series 380W RPS Unit Installation & Administration A EN 55024: 1998 (CISPR24) VCCI Class A AS/NZS 3548 Class A CE CNS 13438 Class A MIC Appendix A: 21 - Linksys SGE2000 | Cisco RPS1000 380W Redundant Power Supply Administration Guide - Page 25
Series 380W RPS Unit Installation & Administration B Troubleshooting The RPS1000 is not power connection to external power. If the AC power is connected properly, the problem might be with the RPS1000 internal power supplies. Output Power LED is amber. The DC output power from the internal power - Linksys SGE2000 | Cisco RPS1000 380W Redundant Power Supply Administration Guide - Page 26
380W RPS Unit Installation & Administration C Linksys Contact Information Need to contact Linksys? Visit us online for information on the latest products and updates to your existing products at: http://www.linksys.com/international If you experience problems with any Linksys product, you can - Linksys SGE2000 | Cisco RPS1000 380W Redundant Power Supply Administration Guide - Page 27
Unit Installation & Administration C E-mail Address [email protected] (English only) [email protected] or [email protected] [email protected] (English only) [email protected] (English only) [email protected] (English only) [email protected] Appendix - Linksys SGE2000 | Cisco RPS1000 380W Redundant Power Supply Administration Guide - Page 28
Appendix RPS1000-Business Series 380W RPS Unit Installation & Administration D Connector and Cable Specifications This appendix describes the cable connector that is used to connect the RPS1000 to a supported device. The cable (CAB-RPS-1614=) is a 48-inch (1.2-meter) cable with a 16-pin - Linksys SGE2000 | Cisco RPS1000 380W Redundant Power Supply Administration Guide - Page 29
Appendix RPS1000-Business Series 380W RPS Unit Installation & Administration D Pin Number 4 5 6 7 8 9 10 11 12 13 14 15 16 14-Pin Designation 12 V 12 V 12 V GND GND -48 V RPS_PRES (RPS1000 present) RPS_CTRL 0 RPS_CTRL 1 PWR_GOOD (power is good) GND 16-Pin Designation 12 V 12 V 12 V GND-12 GND- - Linksys SGE2000 | Cisco RPS1000 380W Redundant Power Supply Administration Guide - Page 30
©2007 Cisco Systems, Inc. All rights reserved. Linksys is a registered trademark and the Linksys One logo is a trademark of Cisco Systems, Inc.
Linksys One Business Series 380W Redundant
Power Supply
Model RPS1000
LINKSYS BUSINESS SERIES RPS1000 INSTALLATION AND ADMINISTRATION GUIDE
Linksys One Business Series RPS1000
Installation and Administration Guide
March 2007