Linksys SPA922 Cisco Small Business IP Phone SPA9X1 Administration Guide - Page 126

Control Timer Values (sec), Call Back Retry Intvl

Page 126 highlights

Chapter 5 Linksys IP Phone Field Reference Field Cadence 1 Cadence 2 Cadence 3 Cadence 4 Cadence 5 Cadence 6 Cadence 7 Cadence 8 Cadence 9 Description Cadence script for distinctive ring 1. Defaults to 60(2/4). Cadence script for distinctive ring 2. Defaults to 60(.3/.2, 1/.2,.3/4. Cadence script for distinctive ring 3. Defaults to 60(.8/.4,.8/4). Cadence script for distinctive ring 4. Defaults to 60(.4/.2,.3/.2,.8/4). Cadence script for distinctive ring 5. Defaults to 60(.2/.2,.2/.2,.2/.2,1/4) Cadence script for distinctive ring 6. Defaults to60(.2/.4,.2/.4,.2/4). Cadence script for distinctive ring 7. Defaults to 60(4.5/4). Cadence script for distinctive ring 8. Defaults to 60(0.25/9.75) Cadence script for distinctive ring 9. Defaults to 60(.4/.2,.4/2). Regional Tab Control Timer Values (sec) Field Reorder Delay (Not applicable to SPA901) Call Back Expires Call Back Retry Intvl Call Back Delay (Not applicable to SPA901) Description Delay after far end hangs up before reorder tone is played. 0 = plays immediately, inf = never plays. Range: 0-255 seconds. Defaults to 255. Expiration time in seconds of a call back activation. Range: 0-65535 seconds. Defaults to 1800. Call back retry interval in seconds. Range: 0-255 seconds. Defaults to 30. Delay after receiving the first SIP 18x response before declaring the remote end is ringing. If a busy response is received during this time, the Linksys IP phone still considers the call as failed and keeps on retrying. Defaults to 0.5. Firmware Version 5.1 Linksys IP Phone Administrator Guide 5-21

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165

5-21
Linksys IP Phone Administrator Guide
Firmware Version 5.1
Chapter 5
Linksys IP Phone Field Reference
Regional Tab
Control Timer Values (sec)
Field
Description
Cadence 1
Cadence script for distinctive ring 1.
Defaults to 60(2/4).
Cadence 2
Cadence script for distinctive ring 2.
Defaults to 60(.3/.2, 1/.2,.3/4.
Cadence 3
Cadence script for distinctive ring 3.
Defaults to 60(.8/.4,.8/4).
Cadence 4
Cadence script for distinctive ring 4.
Defaults to 60(.4/.2,.3/.2,.8/4).
Cadence 5
Cadence script for distinctive ring 5.
Defaults to 60(.2/.2,.2/.2,.2/.2,1/4)
Cadence 6
Cadence script for distinctive ring 6.
Defaults to60(.2/.4,.2/.4,.2/4).
Cadence 7
Cadence script for distinctive ring 7.
Defaults to 60(4.5/4).
Cadence 8
Cadence script for distinctive ring 8.
Defaults to 60(0.25/9.75)
Cadence 9
Cadence script for distinctive ring 9.
Defaults to 60(.4/.2,.4/2).
Field
Description
Reorder Delay
(Not applicable to SPA901)
Delay after far end hangs up before reorder tone is played. 0 = plays immediately, inf =
never plays. Range: 0–255 seconds.
Defaults to 255.
Call Back Expires
Expiration time in seconds of a call back activation. Range: 0–65535 seconds.
Defaults to 1800.
Call Back Retry Intvl
Call back retry interval in seconds. Range: 0–255 seconds.
Defaults to 30.
Call Back Delay
(Not applicable to SPA901)
Delay after receiving the first SIP 18x response before declaring the remote end is
ringing. If a busy response is received during this time, the Linksys IP phone still
considers the call as failed and keeps on retrying.
Defaults to 0.5.