Maytag MEDE900VJ Installation Instructions - Page 4

Side View, Sideview - dimensions

Page 4 highlights

Closet installation - Dryer only Ill , "i-_, 114' max. -,,e.---- [_ _ (34180"c2m*2_) I 18"min,* (460 ram) C A* Side View Steam (Electric or Gas) A* 1" (25 mm) Non-Steam (Electric or Gas) 1" (25 mm) B 7 5/8" (194 mm) 7 5/8" (194 mm) C 3 3/8" (86 mm) 3 3/s" (86 mm) * Dimension A is approximate, depending on when the diamond marking on the leveling foot is no longer visible. See "Venting Requirements." Installation spacing for recessed area or closet installation The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0" (0 mm) clearance on the sides and rear. Recommended spacing should be considered for the following reasons: • Additional spacing should be considered for ease of installation and servicing. • Additional clearances might be required for wall, door, and floor moldings. • Additional spacing should be considered on all sides of the dryer to reduce noise transfer. For closet installation,with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable. • Companion appliance spacing should also be considered. Custom undercounter installation - Dryer only L_J Steam (Electric or Gas) Non-Steam (Electric or Gas) A 0" (0 mm) 0" (0 mm) B 38" (965 mm) 38" (965 mm) C* 1" (25 mm) 1" (25 mm) D 27" (686 mm) 27" (686 mm) E* 1" (25 mm) 1" (25 mm) *Required spacing NOTE: Some models are not recommended for undercounter installation. 4 (12545"Cm22") - -_4A*_,- B -_qO**_,-Side view Closet door with vents Steam (Electric or Gas) Non-Steam (Electric or Gas) A* 1" (25 mm) 1" (25 mm) B 32 9/16"(827 mm) 31 lh" (800 mm) C** 5" (127 mm) 5" (127 mm) *Required spacing **For side or bottom venting, 0" (0 mm) spacing is allowed. Recessed or closet installation - Dryer on pedestal ,_ 18" min.* B--4 D*l E--4 F _ Steam (Electric or Gas) Non-steam (Electric or Gas) A 1" (25 mm) 1" (25 mm) B 27" (686 mm) 27" (686 mm) C 1" (25 mm) 1" (25 mm) D* 1" (25 mm) 1" (25 mm) E 32 9/16"(827 mm) 31 1/2" (800 mm) F** 5" (127 mm) 5" (127 mm) *Required spacing **For side or bottom venting, 0" (0 mm) spacing is allowed NOTE: Some models are not recommended for recessed or closet installation.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16

A*
Side View
C
Steam
Non-Steam
(Electric or Gas)
(Electric or Gas)
A*
1" (25 mm)
1" (25 mm)
B
7 5/8" (194 mm)
7 5/8" (194 mm)
C
3 3/8" (86 mm)
3 3/s" (86 mm)
* Dimension A is approximate,
depending
on when the diamond
marking on the leveling foot is no longer visible.
See "Venting Requirements."
Installation
spacing
for recessed
area or closet
installation
The following spacing dimensions are recommended
for this dryer.
This dryer has been tested for spacing of 0" (0 mm) clearance on the
sides and rear. Recommended
spacing should be considered for the
following
reasons:
Additional
spacing should be considered
for ease of installation
and servicing.
Additional
clearances might be required for wall, door, and floor
moldings.
Additional spacing should be considered
on all sides of the dryer
to reduce noise transfer.
For closet
installation,
with a door, minimum ventilation
openings
in the top and bottom of the door are required. Louvered doors
with equivalent ventilation openings are acceptable.
Companion
appliance spacing should also be considered.
Custom undercounter
installation
-
Dryer only
L_J
Steam
Non-Steam
(Electric or Gas)
(Electric or Gas)
A
0" (0 mm)
0" (0 mm)
B
38" (965 mm)
38" (965 mm)
C*
1" (25 mm)
1" (25 mm)
D
27" (686 mm)
27" (686 mm)
E*
1" (25 mm)
1" (25 mm)
*Required
spacing
NOTE: Some models are not recommended
for undercounter
installation.
Closet installation
-
Dryer only
Ill
,
"i-_,
114' max. -,,e.----
[_
_
48"
2*
(310 cm2)
_
I
18"min,*
(460 ram)
24"2"
(155
Cm2)
-
-_4A*_,-
B
-_qO**_,--
Sideview
Closet door with vents
Steam
Non-Steam
(Electric or Gas)
(Electric or Gas)
A*
1" (25 mm)
1" (25 mm)
B
32 9/16"(827 mm)
31 lh"
(800 mm)
C**
5" (127 mm)
5" (127 mm)
*Required spacing
**For side or bottom
venting,
0" (0 mm) spacing
is allowed.
Recessed
or closet
installation
-
Dryer
on
pedestal
B--4
,_ 18" min.*
D*l
E--4
F_
Steam
Non-steam
(Electric or Gas)
(Electric or Gas)
A
1" (25 mm)
1" (25 mm)
B
27" (686 mm)
27" (686 mm)
C
1" (25 mm)
1" (25 mm)
D*
1" (25 mm)
1" (25 mm)
E
32 9/16"(827 mm)
31 1/2" (800 mm)
F**
5" (127 mm)
5" (127 mm)
*Required spacing
**For side or bottom
venting,
0" (0 mm) spacing
is allowed
NOTE: Some models are not recommended
for recessed or closet
installation.
4