Maytag MGD6300TQ Use and Care Guide - Page 12

i: c I;o}

Page 12 highlights

Make Gas Con i: c I; o}" 1. Remove the red cap from the gas pipe. 2. Using a wrench to tighten, connect the gas supply to the dryer. Use pipe-joint compound on the threads of all non-flared male fittings. If flexible metal tubing is used, be sure there are no kinks. A B... 1. Using a 4" (1 0.2 cm) clamp, connect vent to exhaust outlet in dryer. If connecting to existing vent, make sure the vent is clean. The dryer vent must fit over the dryer exhaust outlet and inside the exhaust hood. Check that the vent is secured to exhaust hood with a 4" (1 0.2 cm) clamp. 2. Move dryer into its final location. Do not crush or kink vent. 3. (On gas modeis) Check that there are no kinks in the flexible gas line. 4. Once the exhaust vent connection is made, remove the corner posts and cardboard. A. fTared male thread B. Non-flared male thread NOTE: For I.P gas connections, you must use pipe-joint compound resistant to the action of I.P gas. I])o not use TEFI.ON _÷ tape. A combination of pipe fittings must be used to connect Shown is a recommended connection. Your connection supply line type, size and location. the dryer to the existing gas line. may be different, according to the Check the levelness of the dryer by first placing a level on the top of the dryer near the conso[e. ! Then, by placing a level in the crease on the side of the dryer between the top of the dryer and the dryer cabinet, check the levelness from front to back. A C B A. a_,,flexible gas connector B. a_,,ctryer pipe C. a_,,to a_,,pipe elbow D. a_,,pipe-to-flare adapter fitting 3. Open the shutoff valve in the supply line. The valve is open when the handle is parallel to the gas pipe. If the dryer is not level, prop up the dryer using a wood block. Use a wrench to adjust the legs up or clown and check again for levelness. A. Closed valve B. Open valve 4° Test all connections by brushing on an approved noncorrosive Bubbles will show a leak. Correct any leak found. leak-detection solution. t-_JFEF[ ON is a registered trademark of E.I. Du Pont De Nemours and Company. 12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

1.
2.
Make
Gas
Con
i: c I;o}"
Remove
the
red
cap
from
the
gas
pipe.
Using
a wrench
to
tighten,
connect
the
gas
supply
to
the
dryer.
Use
pipe-joint
compound
on
the threads
of
all non-flared
male
fittings.
If flexible
metal
tubing
is used, be sure there
are no
kinks.
A
.......................................
-_
...............................
B
A. fTared male
thread
B. Non-flared
male
thread
NOTE:
For I.P gas connections,
you
must
use pipe-joint
compound
resistant
to the
action
of
I.P gas. I])o not
use TEFI.ON _÷ tape.
A combination
of
pipe
fittings
must
be used to
connect
the dryer
to the
existing
gas line.
Shown
is a recommended
connection.
Your connection
may be different,
according
to the
supply
line
type,
size
and
location.
!
1.
Using
a 4" (10.2
cm)
clamp,
connect
vent
to exhaust
outlet
in dryer.
If connecting
to
existing
vent,
make
sure
the vent
is clean.
The dryer
vent
must fit over
the dryer
exhaust
outlet
and
inside
the exhaust
hood.
Check
that
the
vent
is secured
to exhaust
hood
with
a
4" (1 0.2
cm) clamp.
2.
Move
dryer
into
its final
location.
Do
not
crush
or kink
vent.
3.
(On
gas modeis)
Check
that
there
are no
kinks
in the
flexible
gas line.
4.
Once
the
exhaust
vent
connection
is made,
remove
the
corner
posts
and
cardboard.
Check
the
levelness
of the
dryer
by first
placing
a level
on the
top
of the dryer
near the
conso[e.
Then,
by placing
a level
in the crease
on the side
of the
dryer
between
the top
of the
dryer
and
the
dryer
cabinet,
check
the
levelness
from
front
to
back.
3.
A
C
B
A. a_,,flexible gas connector
B. a_,,
ctryer
pipe
C. a_,,to a_,,pipe elbow
D. a_,,pipe-to-flare
adapter
fitting
Open
the shutoff
valve
in the
supply
line.
The valve
is open
when
the
handle
is parallel
to
the
gas pipe.
If the dryer
is not
level,
prop
up the dryer
using
a wood
block.
Use a wrench
to adjust
the
legs
up or clown
and
check
again
for
levelness.
A.
Closed
valve
B. Open valve
Test all connections
by brushing
on an approved
noncorrosive
leak-detection
solution.
Bubbles
will
show
a leak.
Correct
any
leak found.
t-_JFEF[
ON
is a registered
trademark
of
E.I. Du
Pont
De
Nemours
and
Company.
12