Maytag MGDC700VW Installation Instructions - Page 7

NOTE: The following - clearance

Page 7 highlights

Alternate installations for close clearances Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown. Refer to the manufacturer's instructions. Recommended hood styles are shown here. A B A. Over-The-Topinstallation (alsoavailable with one offset elbow) B. Periscope installation NOTE: The following kits for close clearance alternate installations are available for purchase. Please reference the "Assistance or Service" section of the "Dryer User Instructions." [] Over-The-Top Installation: Part Number 4396028 [] Periscope Installation (For use with dryer vent to wall vent mismatch): Part Number 4396037 - 0" (0 cm) to 18" (45.72 cm) mismatch Part Number 4396011 - 18" (45.72 cm) to 29" (73.66 cm) mismatch Part Number 4396014 - 29" (73.66 cm) to 50" (127 cm) mismatch Special provisions for mobile home installations The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside. /q Determine vent length 1. Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. When using elbows or making turns, allow as much room as possible. Bend vent gradually to avoid kinking. Avoid 90 ° turns when possible. 2_ Determine vent length. The maximum length of the exhaust system depends upon: [] The type of vent (rigid metal or flexible metal). [] The number of elbows used. [] Type of hood. B 144,,_' (10.2 cm) A. Louvered hood style B. Box hood style The angled hood style (shown following) is acceptable. 4 fl (10.2 cm)_(_ See the exhaust vent length chart that matches your hood type for the maximum vent lengths you can use. Exhaust systems longer than specified will: [] Shorten the life of the dryer. [] Reduce performance, resulting in longer drying times and increased energy usage. 3_ Determine the number of elbows you will need. NOTE: Do not use vent runs longer than specified in the Vent System Chart. The following chart helps you determine your maximum vent length based on the number of 90 ° turns or elbows you will need and the type of vent (rigid or flexible metal) and hood that you will use. Vent System Chart Number of 90 ° turns or elbows Type of vent Box or Iouvered hoods r r Angled hoods 0 Rigid metal 64 ft (20 m) 58 ft (17.7 m) Flexible metal 36 ft (11 m) 28 ft (8.5 m) 1 Rigid metal 54 ft (16.5 m) 48 ft (14.6 m) Flexible metal 31 ft (9.4 m) 23 ft (7 m) 2 Rigid metal 44 ft (13.4 m) 38 ft (11.6 m) Flexible metal 27 ft (8.2 m) 19 ft (5.8 m) 3 Rigid metal 35 ft (10.7 m) 29 ft (8.8 m) Flexible metal 25 ft (7.6 m) 17 ft (5.2 m) 4 Rigid metal 27 ft (8.2 m) 21 ft (6.4 m) Flexible metal 23 ft (7 m) 15 ft (4.6 m) NOTE: Side and bottom exhaust installations have a 90 ° turn inside the dryer. To determine maximum exhaust length, add one 90 ° turn to the chart.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

Alternate
installations
for close
clearances
Venting systems come in many varieties.
Select the type best for
your installation.
Two close-clearance
installations
are shown.
Refer to the manufacturer's
instructions.
A
B
A. Over-The-Top installation (also
available
with one offset
elbow)
B.
Periscope
installation
NOTE: The following
kits for close clearance alternate
installations
are available for purchase.
Please reference the "Assistance
or
Service"
section of the "Dryer User Instructions."
[]
Over-The-Top
Installation:
Part Number 4396028
[]
Periscope
Installation (For use with dryer vent to wall vent
mismatch):
Part Number 4396037
- 0" (0 cm) to 18" (45.72 cm) mismatch
Part Number 4396011
- 18" (45.72 cm) to 29" (73.66 cm)
mismatch
Part Number 4396014
- 29" (73.66 cm) to 50" (127 cm)
mismatch
Special
provisions
for mobile
home installations
The exhaust
vent must be securely fastened
to a noncombustible
portion
of the mobile home structure
and must not terminate
beneath
the mobile home. Terminate the exhaust
vent outside.
/q
Determine
vent length
1.
Select the route that will provide the straightest
and most
direct path outdoors.
Plan the installation
to use the fewest
number
of
elbows
and turns.
When using
elbows
or making
turns, allow as much room as possible.
Bend vent gradually
to avoid kinking. Avoid 90 ° turns when
possible.
2_
Determine
vent length.
The maximum
length of the exhaust
system depends
upon:
[]
The type of vent (rigid metal or flexible metal).
[]
The number
of elbows
used.
[]
Type of hood.
Recommended
hood styles are shown
here.
B
144,,_'
(10.2 cm)
A. Louvered
hood style
B. Box hood
style
The angled hood style (shown following)
is acceptable.
4 fl
(10.2 cm)_(_
3_
See the exhaust vent length chart that matches your hood
type for the maximum
vent lengths you can use.
Exhaust systems
longer than specified
will:
[]
Shorten
the life of the dryer.
[]
Reduce performance,
resulting in longer drying times and
increased energy usage.
Determine
the number of elbows you will need.
NOTE: Do not use vent runs longer than specified
in the Vent
System Chart.
The following
chart helps you determine
your maximum
vent
length based on the number
of 90 ° turns or elbows you will
need and the type of vent (rigid or flexible metal) and hood
that you will use.
Vent System
Chart
r
r
Number
of
Type of vent
Box or
Angled
90 ° turns
Iouvered
hoods
or elbows
hoods
0
Rigid
metal
64 ft (20 m)
58 ft (17.7 m)
Flexible
metal
36 ft (11 m)
28 ft (8.5 m)
1
Rigid
metal
54 ft (16.5 m)
48 ft (14.6 m)
Flexible
metal
31 ft (9.4 m)
23 ft (7 m)
2
Rigid
metal
44 ft (13.4 m)
38 ft (11.6 m)
Flexible
metal
27 ft (8.2 m)
19 ft (5.8 m)
3
Rigid
metal
35 ft (10.7 m)
29 ft (8.8 m)
Flexible
metal
25 ft (7.6 m)
17 ft (5.2 m)
4
Rigid
metal
27 ft (8.2 m)
21 ft (6.4 m)
Flexible
metal
23 ft (7 m)
15 ft (4.6 m)
NOTE: Side and bottom
exhaust
installations
have a 90° turn
inside the dryer. To determine
maximum
exhaust
length, add one