Maytag MGDE300VF Use and Care Guide - Page 12

of the, following, to follow these

Page 12 highlights

Choose your exhaust installation type Recommended exhaust installations Typical installations vent the dryer from the rear of the dryer. Other installations are possible. B A B C A. Standard rear offset exhaust installation B. Left or right side exhaust installation C. Bottom exhaust installation Alternate installations for close clearances Venting systems come in many varieties. Select the type best for your installation. clearance installations are shown. Refer to the manufacturer's instructions. Two close- A. Dryer B. Elbow C. Waft D. Exhaust hood E.Clamps £ Rigid metal or flexible metal vent C. Vent length necessary to connect elbows H. Exhaust outlet Optional exhaust installations This dryer can be converted to exhaust out the right side, left side or through the bottom. If you prefer, you may contact your local dealer to have the dryer converted Fire Hazard Cover unused exhaust holes with one of the following kits: 279818 (white) W10186596 (midnight grey) Contact your local dealer, Failure to follow these instructions can result in death, fire, electrical shock, or serious injury, , ..... A "'i' ...... B A. Over-the-top insta//ation (also available with one offset elbow) B. Periscope insta//ation NOTE: The following kits for dose clearance alternate installations are available for purchase. Please see the "Assistance or Service" section to order. • Over-the-Top Installation: Part Number 4396028 • Periscope Installation (For use with dryer vent to wall vent mismatch): Part Number 4396037 - 0" (0 cm) to 18" (45.72 cm) mismatch Part Number 4396011 - 18" (45.72 cm) to 29" (73.66 cm) mismatch Part Number 4396014 - 29" (73.66 cm) to 50" (127 cm) mismatch 12

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56

Choose
your
exhaust
installation
type
Recommended
exhaust installations
Typical installations
vent the dryer from the rear of the dryer. Other installations
are possible.
B
A
B
C
A. Standard
rear
offset
exhaust
installation
B. Left or
right
side
exhaust
installation
C.
Bottom
exhaust
installation
Alternate
installations
for
close
clearances
Venting
systems
come
in many
varieties.
Select
the
type
best for your
installation.
Two
close-
clearance
installations
are shown.
Refer to the
manufacturer's
instructions.
A. Dryer
B. Elbow
C.
Waft
D. Exhaust hood
E.
Clamps
£
Rigid metal or flexible metal vent
C.
Vent length necessary to connect
elbows
H. Exhaust outlet
Optional
exhaust
installations
This dryer
can be converted
to exhaust
out
the
right
side,
left side
or through
the bottom.
If
you
prefer,
you
may
contact
your
local
dealer
to
have the dryer
converted
Fire Hazard
Cover unused exhaust holes with one
of the
following
kits:
279818 (white)
W10186596 (midnight grey)
Contact your local dealer,
Failure
to follow these
instructions can result in death,
fire,
electrical
shock, or serious injury,
,
.....
"'i'
......
A
B
A. Over-the-top
insta//ation
(also available
with one offset elbow)
B. Periscope insta//ation
NOTE:
The following
kits for dose
clearance
alternate
installations
are available
for purchase.
Please
see the
"Assistance
or Service"
section
to order.
Over-the-Top
Installation:
Part Number
4396028
Periscope
Installation
(For
use with
dryer
vent
to wall
vent
mismatch):
Part Number
4396037
- 0" (0 cm)
to
18" (45.72
cm)
mismatch
Part Number
4396011
- 18" (45.72
cm) to 29"
(73.66
cm)
mismatch
Part Number
4396014
- 29"
(73.66
cm) to
50" (127
cm)
mismatch
12