NEC NEC-80570 User Guide - Page 18
Trunk and AUX Mod Jacks, Installing Trunk and AUX Mod Jacks, Trunk and Extension Cabling
UPC - 714627059029
View all NEC NEC-80570 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 18 highlights
Trunk and AUX Mod Jacks Trunk and AUX Mod Jacks Installing Trunk and AUX Mod Jacks To connect to mod jacks: 1. Arrange your mod jacks trunk according to Figure 2-1 Installation Layout on page 2-1. 2. Using standard 6-conductor line cords, connect each mod jack to the appropriate plug in the Main Equipment Cabinet. See Figure 2-2 Mod Jack Assignments below. 3. Figure 2-3 Mod Plug Pinouts below shows the pinouts for each mod jack. Audio WHT BLK RED GRN YEL BLU NC Music T Page R Page T Music R NC PFT/MDM WHT BLK RED GRN YEL BLU NC NC PFT/MDM R PFT/MDM T NC NC 80200 - 9C Door Box 1 WHT BLK RED GRN YEL BLU NC Relay 1T DB 1R DB 1T Relay 1R NC Door Box 2* WHT BLK RED GRN YEL BLU NC * Relay 2T * DB 2R * DB 2T * Relay 2R* NC * CO 1-3 WHT 3T BLK 2T RED 1R GRN 1T YEL 2R BLU 3R *Requires Expansion Board Figure 2-2: Mod Jack Assignments CO 4-6* WHT 6T* BLK 5T * RED 4R* GRN 4T * YEL 5R* BLU 6R* 6-Pin Mod Jack Latch faces up 80200 - 10 RJ-25C Port Pin Designation 1 3T 2 2T 3 1R 4 1T 5 2R 6 3R Figure 2-3: Mod Plug Pinouts WHT-BLU (1T) BLU-WHT (1R) WHT-ORN (2T) ORN-WHT (2R) WHT-GRN (3T) GRN-WHT (3R) 2-2 x Section 2: Trunk and Extension Cabling DS1000 Hardware Manual