System Load Factor Calculations
UPC - 714627059029
View all NEC NEC-80570 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 9 highlights
System Preparation and Configuration Default Numbering Voice Mail Ports Ports Station Numbers Extension Numbers - 201-208 500-507 UCD Groups Total Groups UCD Group Master Extension Numbers 8 700-707 Ring Groups Total Groups Ring Group Master Extension Numbers 8 600-607 1 Available for digital station port secondary station numbers. These are used for the second channels on 2-OPX Modules and Digital VANGARD Voice Mail. 1 System Load Factor Calculations The combination of extensions, 2-OPX Modules, and DSS Consoles you can connect to your system may be limited by the System Load Factor. Use the DS1000 System Load Factor Calculations chart to verify your system's configuration. To check your system configuration: 1. Indicate the quantity for each item installed in the Qty column. 2. For each item, multiply the Qty times the Load Factor and enter the value in Total Load. 3. Add all the values in the Total Load column and enter the value in Item 1. 4. Compare the entry in Item 2 to your entry in Item 1. Item 1 must always be equal to or less than the entry in Item 2. Do not operate your system if the System Load Factor total (Item 1) exceeds the allowable load of 30 (Item 2). DS1000 System Load Factor Calculations Description Load Factor Qty Total Load Digital Telephone Analog Telephone Analog Door Box 24-Button DSS Console 110-Button DSS Console 2-OPX Module 1 1 0 1 2 Total DSS Consoles installed cannot exceed 4 3 Item 1: Total load for this configuration Item 2: Maximum allowable load 30 DS1000 Hardware Manual Section 1: Installation Basics x 1-3