NEC NEC-80570 User Guide - Page 26

External Paging Relay Control, Connecting the Relays for External Paging Control

Page 26 highlights

External Paging External Paging Relay Control You can alternately use the 2 Door Box relays to control an External Paging amplifier. Figure 4-2 Connecting an Analog Door Box on page 4-4 shows you the location of the Door Box relays. Note that if you use a relay for External Paging Control, you cannot also use it for Door Box strike control. !! Important !! Be sure the devices connected to the system's relay contacts are compatible with the following specifications. Relay Contact Specifications Contact Configuration: Normally Open Maximum Load: Maximum Initial Contact Resistance: 0.5A @ 120 VAC 1 A @ 24 VDC 100 mOhms Connecting the Relays for External Paging Control 1. If you are using the Door 1 relays, connect the BLK and YEL lugs on the Door Box 1 modular jack to the relay that controls the External Paging system. 2. If you are using the Door 2 relays, connect the BLK and YEL lugs on the Door Box 2 modular jack to the relay that controls the External Paging system. Programming the Relays for External Paging Control q In 0201 - Door 1 Relay, to assign the Door 1 Relay for External Paging control, enter 2. q In 0201 - Page Zone (Door 1 Relay), enter the Page Zone (1-7) that should activate the Door 1 relay. Note that Zone 1 and All Call Paging announcements broadcast from the External Paging output. q In 0201 - Door 2 Relay, to assign the Door 2 Relay for External Paging control, enter 2. q In 0201 - Page Zone (Door 2 Relay), enter the Page Zone (1-7) that should activate the Door 2 relay. Note that Zone 1 and All Call Paging announcements broadcast from the External Paging output. 4-2 x Section 4: Optional Equipment DS1000 Hardware Manual

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

External Paging
4-2
Section 4: Optional Equipment
DS1000 Hardware Manual
External Paging Relay Control
You can alternately use the 2 Door Box relays to control an External Paging amplifier. Figure 4-2
Connect-
ing an Analog Door Box
on page 4-4 shows you the location of the Door Box relays. Note that if you use a
relay for External Paging Control, you cannot also use it for Door Box strike control.
Connecting the Relays for External Paging Control
1.
If you are using the Door 1 relays, connect the BLK and YEL lugs on the Door Box 1 modular jack to
the relay that controls the External Paging system.
2.
If you are using the Door 2 relays, connect the BLK and YEL lugs on the Door Box 2 modular jack to
the relay that controls the External Paging system.
Programming the Relays for External Paging Control
In
0201 - Door 1 Relay
, to assign the Door 1 Relay for External Paging control, enter 2.
In
0201 - Page Zone (Door 1 Relay)
, enter the Page Zone (1-7) that should activate the Door 1 relay.
Note that Zone 1 and All Call Paging announcements broadcast from the External Paging output.
In
0201 - Door 2 Relay
, to assign the Door 2 Relay for External Paging control, enter 2.
In
0201 - Page Zone (Door 2 Relay)
, enter the Page Zone (1-7) that should activate the Door 2 relay.
Note that Zone 1 and All Call Paging announcements broadcast from the External Paging output.
!! Important !!
Be sure the devices connected to the system’s relay contacts
are compatible with the following specifications.
Relay Contact Speci
cations
Contact Configuration:
Normally Open
Maximum Load:
0.5A @ 120 VAC
1 A @ 24 VDC
Maximum Initial Contact Resistance:
100 mOhms