Panasonic 26PEK1U6 Tech Data - Service Manual - Page 184
Monitoring Operations: Display of Indoor Unit and Outdoor Unit Sensor Temperatures
View all Panasonic 26PEK1U6 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 184 highlights
5. Outdoor unit maintenance remote control 5-4. Monitoring Operations: Display of Indoor Unit and Outdoor Unit Sensor Temperatures (1) Press and hold the button and button simultaneously for 4 seconds or longer to switch to temperature monitor mode. During temperature monitoring, "Service Monitor" is lit. (The display and operations are the same as when monitor mode is started from the unit remote controller.) (2) Press the button and select the indoor unit to monitor. (4) (3) Use the temperature setting and buttons to select the item code of the temperature to monitor. The selected indoor unit No. and the temperature data are displayed. (3) (1) (2) (4) To end monitoring, press the button. The display returns to the normal display. * The display does not blink. Indoor unit data Outdoor unit data Item code 02 03 04 05 06 07 08 09 0A 0b 0C 0d 0E 0F 10 11 12 13 14 15 19 Meaning of Code Indoor unit intake temp. Indoor unit heat exchanger temp. (E1) Indoor unit heat exchanger temp. (E2) - Indoor unit discharge temp. - - Discharge temp. (TD) - - Intake temp. (TS) Outdoor unit heat exchanger temp. (C1) Outdoor unit heat exchanger temp. (C2) - Outdoor air temp. (TO) - - Current value Outdoor MV value Frequency * Depending on the model, some items may not be displayed. 5 5-6