Panasonic AE3000U Operating Instructions - Page 48

Care and Replacement, Removing and replacing the lamp unit, Attaching the top cover, Resetting - lamp replacement

Page 48 highlights

Care and Replacement J Removing and replacing the lamp unit 1. Use a Phillips screwdriver to loosen the 3 lamp unit fixing screws until the screws turn freely. Lamp unit fixing screws 4. Replace the new lamp unit while making sure that the direction of insertion is correct. Press the top of the lamp unit and make sure the unit is installed securely. Press here Press here Lamp unit lock 2. Hold the handle of the lamp unit and release the lamp unit lock. 3. Pull out the lamp unit gently from the projector. J Attaching the top cover 1. Attach the hinge parts of the top cover to the projector and press slightly until it clicks. When the projector is mounted on the ceiling, attaching the hinge parts is not required. 2. Hook the top cover safety hook to the projector. 3. Hooking the tabs of the top cover to the front of the projector and lift down slowly. 4. Press the back corner of the top cover gently until it clicks. Make sure to hook the top cover safety hook to the body. 5. Tighten the lamp unit fixing screws securely with a Phillips screwdriver. Top cover safety hook Hinge part NOTE: • Be sure to install the lamp unit and the top cover of the projector securely. If they are not securely installed, it may cause the protection circuit to operate so that the power cannot be turned on. • Grip the handle and keep the lamp unit paralleled when you remove the lamp unit. • Do not switch the power on while the top cover is opened. • When the projector is mounted on the ceiling, keep the lamp unit paralleled up and remove. J Resetting the LAMP RUNTIME If the lamp usage time has passed 2 000 hours (when LAMP POWER has been set to NORMAL), the projector will switch to standby mode after approximately 10 minutes of operation. The resetting procedure should thus be completed within 10 minutes. 1. Connect the power cord to the projector and a wall 6. Press and hold the ENTER button for outlet, and switch the MAIN POWER on. approximately 3 seconds. 2. Switch the power button. 7. The confirmation screen will be displayed and 3. Press the MENU button to display the menu. 4. Press F G to select OPTION and press ENTER. 5. Press F G to select LAMP RUNTIME. select OK. 8. Switch off the power button to reset the duration of the LAMP RUNTIME. 9. Confirm the duration of time in LAMP RUNTIME is LAMP POWER STANDARD reset to "0". LAMP RUNTIME 1820H Maintenance 48 - ENGLISH

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

Maintenance
Care and Replacement
48 -
E
NGLISH
Removing and replacing the lamp unit
1.
Use a Phillips screwdriver to loosen the 3 lamp unit
fixing screws until the screws turn freely.
2.
Hold the handle of the lamp unit and release the
lamp unit lock.
3.
Pull out the lamp unit gently from the projector.
4.
Replace the new lamp unit while making sure that
the direction of insertion is correct.
Press the top of the lamp unit and make sure the unit
is installed securely.
5.
Tighten the lamp unit fixing screws securely with a
Phillips screwdriver.
Attaching the top cover
1.
Attach the hinge parts of the top cover to the
projector and press slightly until it clicks.
When the projector is mounted on the ceiling,
attaching the hinge parts is not required.
2.
Hook the top cover safety hook to the projector.
3.
Hooking the tabs of the top cover to the front of the
projector and lift down slowly.
4.
Press the back corner of the top cover gently until
it clicks.
Make sure to hook the top cover safety hook to the
body.
Resetting the LAMP RUNTIME
If the lamp usage time has passed 2 000 hours (when
LAMP POWER
has been set to
NORMAL
), the
projector will switch to standby mode after approximately 10 minutes of operation. The resetting procedure
should thus be completed within 10 minutes.
1.
Connect the power cord to the projector and a wall
outlet, and switch the
MAIN POWER
on.
2.
Switch the power button.
3.
Press the
MENU
button to display the menu.
4. Press
F
G
to select
OPTION
and press
ENTER
.
5. Press
F
G
to select
LAMP RUNTIME
.
6.
Press and hold the
ENTER
button for
approximately 3 seconds.
7.
The confirmation screen will be displayed and
select
OK
.
8.
Switch off the power button to reset the duration of
the
LAMP RUNTIME
.
9.
Confirm the duration of time in
LAMP RUNTIME
is
reset to "0".
Lamp unit
fixing screws
Lamp unit lock
Press here
Press here
Top cover safety hook
Hinge part
NOTE:
Be sure to install the lamp unit and the top cover of the projector securely. If they are not
securely installed, it may cause the protection circuit to operate so that the power cannot be
turned on.
Grip the handle and keep the lamp unit paralleled when you remove the lamp unit.
Do not switch the power on while the top cover is opened.
When the projector is mounted on the ceiling, keep the lamp unit paralleled up and remove.
STANDARD
1820H
LAMP POWER