Panasonic AW-HS50 Operating Instructions

Panasonic AW-HS50 Manual

Panasonic AW-HS50 manual content summary:

  • Panasonic AW-HS50 | Operating Instructions - Page 1
    Operating Instructions Compact Live Switcher AW-HS50N Model No. 3TR006599BAA
  • Panasonic AW-HS50 | Operating Instructions - Page 2
    Instructions 1-1-6. Manual transitions KEY 10 1-3-1. Concerning key combinations 10 1-3-2. Setting the PinP and KEY priority 10 1-3-3. Selecting the key materials 11 1-3-4. Key transition 11 1-3-5. Key setup 12 1-3-6. Key adjustments 14 1-3-7. Chroma key 1-8. Setting the USER buttons 24 1-9.
  • Panasonic AW-HS50 | Operating Instructions - Page 3
    to install the software 48 6-4. Basic operations of software 48 6-5. AW-RP50 .....56 7-2-6. Sending and receiving the tally information 56 Table of menu items 57 Appendix (glossary 65 How the model's Operating Instructions manuals are configured  The manual of this Compact Live Switcher
  • Panasonic AW-HS50 | Operating Instructions - Page 4
    is achieved. Concerning the Operating Instructions  For the purposes of these instructions, AW-HS50N is referred to as "AW-HS50". Similarly, AW-HE50HN and AW-HE50SN are referred as "AW-HE50," and AW-RP50N is referred to as "AW-RP50".  In these instructions, the phrases "pan-tilt head
  • Panasonic AW-HS50 | Operating Instructions - Page 5
    on the right of the A and B crosspoint buttons light. POWER ALARM LINK USER 1 3 USER 2 4 SHIFT OSD/TIME OSD ON AUX PinP KEY-F/S BUS DELEGATION MIX WIPE TRANSITION TYPE PinP ON KEY ON FTB ON KEY-S AUX PGM 16 KEY-F PinP AUX PVW 27 KEY OUT 38 CLN 49 MV 5 10 A SHIFT B SHIFT CUT AUTO
  • Panasonic AW-HS50 | Operating Instructions - Page 6
    to select the background transition mode. 1-1-6. Manual transitions Operate the slide lever to execute transitions manually. If the slide lever is moved while the slide lever. BKGD: Background transition KEY: Key transition PinP: PinP transition NoAsign: Transitions are not executed even when the slide
  • Panasonic AW-HS50 | Operating Instructions - Page 7
    50p: max 19s49f 24PsF: max 41s15f 23.98PsF: max 41s15f  Even when the "Key", "PinP" or "NoAsign" has been selected as the setting of the slide lever is pressed, the background transition is executed instantly.  Even when the "Key", "PinP" or "NoAsign" has been selected as the setting of the
  • Panasonic AW-HS50 | Operating Instructions - Page 8
    1. Basic operations 1-2. Wipe Wipe patterns or borders can be set for executing the background transition. =?9+2'/GPW 2CVVGTP  &KTGEVKQP 04 $QTFGT5QHV $^5 5GV$QTFGT%QN 9JKVG #FL$QTFGT%QN *^5 2QUKVKQP 5GV6Q2TGUGV  1-2-1.
  • Panasonic AW-HS50 | Operating Instructions - Page 9
    When the submenu [2] WIPE Menu is displayed, direct operations using the USER buttons and OSD/TIME dial are enabled.  Refer to "2-5-6. Direct operations using the USER buttons and OSD/TIME dial" ( Operating Instructions). U1: Pos-X (X coordinate), U2: Pos
  • Panasonic AW-HS50 | Operating Instructions - Page 10
    the image to be combined with the background. How key combinations work is shown in the figure below. Background Key source Invert HS50 Output image HS50 Key fill 1-3-2. Setting the PinP and KEY priority Besides keys, PinP (picture in picture) is also available as
  • Panasonic AW-HS50 | Operating Instructions - Page 11
    by operating the slide lever. [13] Operation Menu 7. Slide Lever AUX PinP KEY-F/S BUS DELEGATION MIX WIPE TRANSITION TYPE PinP ON KEY ON FTB ON KEY-S AUX PGM 16 KEY-F PinP AUX PVW 27 KEY OUT 38 CLN 49 MV 5 10 A SHIFT B SHIFT 2 CUT AUTO BKGD 11
  • Panasonic AW-HS50 | Operating Instructions - Page 12
    setting is used when the key source signal and key fill signal are different. Chroma (Chroma key: Self key): The key signal is created using a specific hue of the key fill signal as a reference. Since the luminance key and chrominance key function as self keys, the key fill signal is used as the
  • Panasonic AW-HS50 | Operating Instructions - Page 13
    Edge Col This item is used to adjust the hue (H), saturation (S) and luminance (L) of the color which has been set for the edges. Edge Direction [4] KEY Setup Menu 7. Edge Direction This item is used to set the direction (in 45-degree increments) in which to add "Drop" or "Shadow". (Top) 180
  • Panasonic AW-HS50 | Operating Instructions - Page 14
    key and linear key.  The item cannot be used when Chroma (chroma key/self key) has been selected as the key type. Gain [5] KEY USER buttons and OSD/TIME dial" ( Operating Instructions). U1: Mask-L, U2: Mask-R, U3: Mask-T, U4: Mask-B Mask Invert [5] KEY
  • Panasonic AW-HS50 | Operating Instructions - Page 15
    /TIME dial" ( Operating Instructions). U1: Pos-X (X coordinate), U2: Pos-Y (Y coordinate), U3: Size, U4: Aspect (Aspect ratio) Sampling is initiated when the OSD/TIME dial is pressed after the sample marker has been adjusted.  Y Oval-shaped chroma key 15
  • Panasonic AW-HS50 | Operating Instructions - Page 16
    color muting. The color muting is adjusted when the background color is superimposed over the subject.  Memo  Knack of adjusting the chroma key The chroma key adjustments are facilitated by following the steps below.  Initiate automatic sampling, and decide on the color to be defined.  Using the
  • Panasonic AW-HS50 | Operating Instructions - Page 17
    by operating the slide lever. [13] Operation Menu 7. Slide Lever AUX PinP KEY-F/S BUS DELEGATION MIX WIPE TRANSITION TYPE PinP ON KEY ON FTB ON KEY-S AUX PGM 16 KEY-F PinP AUX PVW 27 KEY OUT 38 CLN 49 MV 5 10 A SHIFT B SHIFT 2 CUT AUTO BKGD 17
  • Panasonic AW-HS50 | Operating Instructions - Page 18
    buttons and OSD/TIME dial are enabled.  Refer to "2-5-6. Direct operations using the USER buttons and OSD/TIME dial" ( Operating Instructions). U1: Pos-X (X coordinate), U2: Pos-Y (Y coordinate), U3: Size, U4: - Note The size of the image cannot be changed
  • Panasonic AW-HS50 | Operating Instructions - Page 19
    trimmed. 4:3: The image is automatically trimmed so that its aspect ratio is 4:3. Manual: The image is trimmed in the area which has been set using the "7. Trim has been registered in the preset memories can be called using the USER buttons.  Before any settings are registered or recalled, "PinP
  • Panasonic AW-HS50 | Operating Instructions - Page 20
    1. Basic operations 1-4-4. Transition between PinP materials When a PinP bus material has been selected, the effect to be produced when images are switched can be executed as a MIX transition. (Bus transition function)  When one material set to the Dot by Dot mode and another material have been
  • Panasonic AW-HS50 | Operating Instructions - Page 21
    where the PinP image settings were registered is called using the USER buttons.  Before using the function, set the transition duration and  Soft effect amount  Trimming area setting (Value which has been set in the Manual mode) 1-4-6. Selecting the Dot by Dot mode When 1080/59.94i or 1080/50i
  • Panasonic AW-HS50 | Operating Instructions - Page 22
    1. Basic operations 1-5. FTB (fade to black) Pressing the FTB ON button initiates fade-out from the program image to a black screen or fade-in from a black screen to the program image for the transition duration which has been set. [1] TIME/CBGD Menu 4. FTB Time <
  • Panasonic AW-HS50 | Operating Instructions - Page 23
    Select the material using the A bus or B bus crosspoint buttons. [A bus crosspoint buttons] When buttons [1], [2], [3], [4] and [5] are pressed, PGM, PVW, KEY OUT, CLN or MV are selected, respectively. [B bus crosspoint buttons] When the buttons from [1] to [5] are pressed, the materials assigned to
  • Panasonic AW-HS50 | Operating Instructions - Page 24
    the chroma key marker is displayed  When the submenu [2] WIPE Menu is displayed  When the submenu [3] PinP Menu is displayed  When the submenu [5] KEY Adjust Menu is displayed  Refer to "2-5-6. Direct operations using the USER buttons and OSD/TIME dial" ( Operating Instructions). 24
  • Panasonic AW-HS50 | Operating Instructions - Page 25
    it in the flash memory area which is incorporated inside the unit. [12] USER/FMEM Menu 6. AUX To FMEM Rv (Review): This setting determines whether the review frame, names of the materials, tally information, audio level meter PGM PGM INPUT1 INPUT2 INPUT5 INPUT6 AUX AUX INPUT3 FMEM1
  • Panasonic AW-HS50 | Operating Instructions - Page 26
    inside the unit. Whether to automatically save the image data stored in the frame memories or save it manually is set when the data is to be transferred from the AUX bus. [12] USER/FMEM Menu 7. FMEM Mode M (Mode): This is used to set the method of storing the image data in
  • Panasonic AW-HS50 | Operating Instructions - Page 27
       Input connector SDI IN 1, SDI IN 2 SDI IN 3, SDI IN 4 DVI IN VPrc 2-1-6  Setting menu items and sections in this manual UC DVI-IN scaling DVI-IN information display 2-1-7 2-1-8 2-1-9 - - -   - - - -   : Can be set; -: cannot be set To set the input signals, display
  • Panasonic AW-HS50 | Operating Instructions - Page 28
    default settings (INPUT1 to INPUT5) are used. Preset: The material names provided ahead of time are used. The names are set using the "Name" item. User: A material name is set using up to 10 characters. The actual material names are set using the "Name" item. CAM Name: When an IP connection
  • Panasonic AW-HS50 | Operating Instructions - Page 29
    used to set the material names. Material names can be set when "Preset" or "User" has been selected as the material name type setting.  The material names are merely . Turn the OSD/ TIME dial to select the number. When "User" is selected Any material names consisting of not more than 10 characters
  • Panasonic AW-HS50 | Operating Instructions - Page 30
    2. Input/output signal settings 2-1-5. Freezing and canceling the freezing of the input images [10.1] Input Menu/SDI-IN1 3. Freeze [10.2] Input Menu/SDI-IN2 3. Freeze [10.3] Input Menu/SDI-IN3 3. Freeze [10.4] Input Menu/SDI-IN4 3. Freeze [10.5] Input Menu/DVI-IN 1. Freeze These are used to freeze
  • Panasonic AW-HS50 | Operating Instructions - Page 31
    is used to set the scaling for the DVI-D input signal images. Listed below are the resolutions of the images which can be input. Resolutions supported XGA 1024  768/60 Hz WXGA 1280  768/60 Hz SXGA 1280  1024/60 Hz WSXGA+ 1680  1050/60 Hz UXGA 1600  1200/60 Hz
  • Panasonic AW-HS50 | Operating Instructions - Page 32
    2. Input/output signal settings Table of DVI input scaling sizes DVI format XGA 1024  768 Mode Fit-V HD/1080i 1920  1080   HD/720P 1280  720   Fit-H SD/NTSC 720  487 720 487 720 487 SD/PAL 720  576 720 576 720 576 SXGA 1280  1024 FULL   Fit-V   Fit
  • Panasonic AW-HS50 | Operating Instructions - Page 33
    2. Input/output signal settings DVI format WSXGA+ 1680  1050 Mode Fit-V HD/1080i 1920  1080 1728 1080 Fit-H HD/720P 1280  720 1152 720 SD/NTSC 720  487 SD/PAL 720  576 UXGA 1600  1200 FULL 1920 1080 Fit-V 1440 1080 Fit-H WUXGA 1920  1200 FULL 1920 1080 Fit-V 1728 1080 Fit-H
  • Panasonic AW-HS50 | Operating Instructions - Page 34
    This indicates the vertical frequency of the images. Dot Clock: This indicates the dot clock frequency of the images. The formats supported are listed below. Input video signal XGA WXGA SXGA WSXGA+ WUXGA UXGA 1080/50p 1080/59.94p 1024  768 1280  768 1280  1024 1680
  • Panasonic AW-HS50 | Operating Instructions - Page 35
    available. PGM This is the main line output of the switcher. Images with wipe, mix, key, PinP or other effects added are output. PVW The PVW to set the resolution to be output. The following resolutions are supported. Supported resolutions Auto Using the DVI signals, the information of the
  • Panasonic AW-HS50 | Operating Instructions - Page 36
    2. Input/output signal settings [11] Output Menu 6. DVI-OUT:Scale This is used to select one of the scaling methods listed below. Fit-V The aspect ratio of the output image is maintained, and the size of the image is enlarged or reduced in accordance with the vertical resolution.  Black images
  • Panasonic AW-HS50 | Operating Instructions - Page 37
    set the signals to be displayed in split screens 1 to 10. SDI-IN1 to 4 (material names) CBGD FMEM1 PVW DVI-IN (material names) FMEM2 PGM KEY OUT AUX  Depending on the setting selected for the "1. Split" item, the "6. Pos5 Source" to "11. Pos10 Source" items may not be displayed.
  • Panasonic AW-HS50 | Operating Instructions - Page 38
    3. Setting the multi view display 3-2. Setting the split frames and characters The frames, character luminance and background to be used for the split screens can be set. The settings are selected on the [8] MultiView Out/Frame Menu of the OSD menu. =?/WNVK8KGY1WV(TCOG/GPW (TCOG %
  • Panasonic AW-HS50 | Operating Instructions - Page 39
    display 3-4. Setting the level meters Level meters for the embedded audio signals transferred by the SDI input can be displayed on when the signals from a remote camera controlled by the AW-RP50 are input.  It appears only when the unit and the AW-RP50 are linked. [8] MultiView Out/Frame Menu 6.
  • Panasonic AW-HS50 | Operating Instructions - Page 40
    "Locked" has been set using the menu item below. [13] Operation Menu 11. SYSTEM Menu [14] SYSTEM Menu 1. Format Select the supported format from among the options provided below. Supported formats 1080/59.94i 1080/50i 720/59.94p 720/50p 1080/24PsF 1080/23.98PsF 480/59.94i 576/50i
  • Panasonic AW-HS50 | Operating Instructions - Page 41
    input materials selected by the AUX bus are allowed to pass through. Off: The ancillary data and embedded audio data are not allowed to pass through.  The data is not allowed to pass through when KEY OUT or CLN material has been selected. [14] SYSTEM Menu 5. PGM Anci On or Off is selected
  • Panasonic AW-HS50 | Operating Instructions - Page 42
    values.  However, the video format settings and the network settings will not be initialized. 4-1-4. Network settings The network settings for upgrading the software versions and other data can be selected. [14] SYSTEM Menu 9. IP Address This is used to set the IP address. Initial value: 192
  • Panasonic AW-HS50 | Operating Instructions - Page 43
    4. System settings 4-2. Operation menu settings 4-2-1. OSD (on-screen display) settings The menu screens can be superimposed onto the images output from the SDI OUT 2 connector and DVI OUT connector, and displayed. =?1RGTCVKQP/GPW 15&176 15&5K\G 15&$CEM -G[2TKQTKV[ $WU/QFG
  • Panasonic AW-HS50 | Operating Instructions - Page 44
    Key Priority  Refer to "1-3. KEY". [13] Operation Menu 5. Bus Mode  Refer to "1-1-4. Selecting the bus mode". [13] Operation Menu 6. Time Unit  Refer to "1-1-7. Auto transition". [13] Operation Menu 7. Slide Lever  Refer to "1-1-6. Manual to set the link function with the AW-RP50 to ON or OFF. On
  • Panasonic AW-HS50 | Operating Instructions - Page 45
    0Q#NCTO 0Q#NCTO 0Q#NCTO [15] SYSTEM Status SYSTEM Ver. The system version information is displayed here. [15] SYSTEM Status SOFT Ver. The unit's software version is displayed here. [15] SYSTEM Status GLUE FPGA Ver. The version of the hardware used to start the unit is displayed here. [15] SYSTEM
  • Panasonic AW-HS50 | Operating Instructions - Page 46
    AW-HE50 and AW-RP50 connections and settings, refer to "2-2-2. Example of connections" ( Operating Instructions signal is output when trouble has occurred. A low level is output during key combinations. This signal Max. 50 mA AW-HS50 (Max. voltage: 24 V) TALLY OUT1 - 5 ALARM KEY ON (Max.
  • Panasonic AW-HS50 | Operating Instructions - Page 47
    installed into the host computer from the CD-ROM provided. For details on how to install the application, refer to "6-3. How to install the software". 6-2. Connections A LAN cable is used to connect the host computer to the unit's LAN connector. When connecting the unit directly to the host computer
  • Panasonic AW-HS50 | Operating Instructions - Page 48
    the hard disk drive of the host computer. 6-4. Basic operations of software This section describes how to operate the Data Transmission Software. 1. Double-click on "HS50Tool.exe" in the "Data Transmission Software" folder which was copied. Click the [CLOSE] button.
  • Panasonic AW-HS50 | Operating Instructions - Page 49
    that [To HS50] appears in the [Mode] field in the "Image Data". If [From HS50] appears instead, click the [From HS50] button so that [To HS50] appears. 2. the size. If the image is in a different video format from the ones supported by the unit, the output will not be displayed properly. 5. In the [
  • Panasonic AW-HS50 | Operating Instructions - Page 50
    6-5-2. Transferring the unit's image data to the computer 1. Select the mode. Check that [From HS50] appears in the [Mode] field. If [To HS50] appears instead, click the [To HS50] button so that [From HS50] appears. 2. Select the data to be imported to the host computer in the [Target] field
  • Panasonic AW-HS50 | Operating Instructions - Page 51
    6. Connections with a computer 6-6. Transferring the setup data 6-6-1. Transferring the setup data from the computer to the unit 1. Select "Upload Setup Data" under "Setup Data", and click the [EXEC] button. 2. On the screen which is now displayed, select the setup data to be transferred from the
  • Panasonic AW-HS50 | Operating Instructions - Page 52
    6. Connections with a computer 6-7. Importing the log data The log data recorded in the unit can be imported to a computer. 1. Click the [EXEC] button under "Log Data". 2. On the screen which is now displayed, select the folder and file containing the log data, and click [Save]. (The file extension
  • Panasonic AW-HS50 | Operating Instructions - Page 53
    address of the switcher (this unit) to be linked.  Enable the function for linking with the switcher (SWLINK). For further details on the setting methods, refer to the Operating Instructions accompanying the AW-RP50. LAN cable LINK indicator: Lights. LAN cable Switching hub AW-HS50 AW-RP50 53
  • Panasonic AW-HS50 | Operating Instructions - Page 54
    switcher bus materials The unit's bus materials can be switched in tandem with the camera selection operations performed by the AW-RP50. [Settings established at the AW- using the CAMERA STATUS/SELECTION button. AW-HS50 AW-RP50 USER button indicator: Off AW-RP50 USER button indicator: Lights 54
  • Panasonic AW-HS50 | Operating Instructions - Page 55
    The following setting information of the remote cameras captured by the AW-RP50 can be displayed on the unit's AUX bus output image Remote camera name (displayed with up to 10 characters)  1080/59i 1/100  USER AUTO , CLOSE Notes  The information is not displayed for outputs from the SDI
  • Panasonic AW-HS50 | Operating Instructions - Page 56
    lever and ZOOM button on the AW-RP50 operations take effect. [3] PinP Menu The PinP position can be changed using the PAN/TILT lever, and the PinP size can be changed using the ZOOM button. [6] ChromaKey Menu While the chroma key marker is displayed, the chroma key marker position can be changed
  • Panasonic AW-HS50 | Operating Instructions - Page 57
    Menu 2 WIPE Menu 3 PinP Menu Setting item 1 AUTO Time 2 PinP Time 3 KEY Time 4 FTB Time 5 FTB Source 6 AUX BUS Trans 7 PinP BUS Trans 8 to 359.9 H Initial value 0.0 0.0 to 100.0 S 0.0 0.0 to 108.0 L 100.0 Setting range Manual, Off, 4:3 Initial value Off -50.00 to 50.00 L -40.00 -50.00 to 50
  • Panasonic AW-HS50 | Operating Instructions - Page 58
    Table of menu items No. Sub menu 4 KEY Setup Menu 5 KEY Adjust Menu 6 ChromaKey Menu Setting item 1 Key Type 2 Fill 3 PVW 4 Set Fill Col Cancel Setting Setting range Luminance(ChrmOff), Luminance(ChrmOn), Linear, Chroma Initial value Luminance(ChrmOff) Setting range Bus, Matte Initial value
  • Panasonic AW-HS50 | Operating Instructions - Page 59
    AUX Initial value FMEM1 Setting range SDI-IN1 to 4 DVI-IN CBGD, FMEM1, FMEM2, PGM, PVW, KEY OUT, AUX Initial value FMEM2 Setting range SDI-IN1 to 4 DVI-IN CBGD, FMEM1, FMEM2, PGM, PVW, KEY OUT, AUX Initial value AUX Setting range LUM0%, LUM25%, LUM50%, LUM75%, LUM100%, Off Initial value LUM75
  • Panasonic AW-HS50 | Operating Instructions - Page 60
    Select Setting range Frame, Field Initial value Frame 3 Freeze Setting range On, Off Initial value Off 4 Name Type Setting range Default, Preset, User, CAM Name Initial value Default 5 Name Setting range Max. 10 characters can be set Initial value INPUT1 6 VPrc/YGain/Ped Setting range
  • Panasonic AW-HS50 | Operating Instructions - Page 61
    Select Setting range Frame, Field Initial value Frame 3 Freeze Setting range On, Off Initial value Off 4 Name Type Setting range Default, Preset, User, CAM Name Initial value Default 5 Name Setting range Max. 10 characters can be set Initial value INPUT3 6 VPrc/YGain/Ped Setting range
  • Panasonic AW-HS50 | Operating Instructions - Page 62
    Table of menu items No. Sub menu 11 Output Menu 12 USER/FMEM Menu Setting item 1 SDI-OUT1 2 SDI-OUT2 3 DVI-OUT 4 SDI-OUT 1 to 5 Initial value 3 Setting range PinP Preset, WIPE Preset, PinP PVW, KEY PVW, GPI Input, GPI Output, CamCont Link, AUX Transition, PinP Transition, EFFDSLV, StrFMEM1
  • Panasonic AW-HS50 | Operating Instructions - Page 63
    Table of menu items No. Sub menu 13 Operation Menu 14 SYSTEM Menu 15 SYSTEM Status Setting item 1 OSD OUT 2 OSD Size 3 OSD Back 4 Key Priority 5 Bus Mode 6 Time Unit 7 Slide Lever 8 GPI Input 9 GPI Output 10 CamCont Link 11 SYSTEM Menu 1 Format 2 HiResMV 3 16:9SQ 4 AUX Anci 5 PGM Anci 6
  • Panasonic AW-HS50 | Operating Instructions - Page 64
    Table of menu items No. Sub menu BUS Assign Status Name of the currently set material Setting item XPT SW XPT SW Asign PGM PVW AUX PinP KEY Fill KEY Source 1 to 10 Setting Display only SDI-IN1 to 4 DVI-IN FMEM1, FMEM2, CBGD, CBAR, Black, NoAsign 64
  • Panasonic AW-HS50 | Operating Instructions - Page 65
    used in this manual. Word Explanation key. Its width and color can be adjusted. The defocusing of the area around a border is referred to as the soft effect. Chroma key This refers to the function for creating the key handled by DVI-D. Embedded Audio This refers to the audio data packets which
  • Panasonic AW-HS50 | Operating Instructions - Page 66
    standard by which video signals in various SD and HD formats are transmitted along a single coaxial cable. A function that creates key signals from key fill signals for combining keys. The memory in which the control panel statuses can be saved and recalled. The button selection statuses as well as
  • Panasonic AW-HS50 | Operating Instructions - Page 67
    Memo
  • Panasonic AW-HS50 | Operating Instructions - Page 68
    © Panasonic System Networks Co., Ltd. 2010 F0610Y1070 D
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68

Operating Instructions
<Operations and Settings>
Compact Live Switcher
Model No.
AW-HS50N
3TR006599BAA