Philips LC3136 User Manual - Page 29

Lamp Replacement - replacement lamp

Page 29 highlights

6. Maintenance > Lamp Warning: Lamplife has almost expired It is suggested to have a spare lamp available. The lamp type is indicated in the user guide. When operation time reaches the last 100 hours of the average lamplife, the message 'Warning: lamplife has almost expired' will be displayed on the screen, each time the projector is switched on.The lamp indicator lights up orange. AV Mute Stand by Source Lamp Temp Menu OK Display Picture (previous) Start-up screen Lamp counter Auto standby Auto source Feedback Audio Settings Lamp 5 Hours Lamp counter shows the operating hours of the lamp. It is suggested to reset when a new lamp is inserted. To reset keep OK key pressed for 3 seconds. Warning: Lamplife has expired It is suggested to change the lamp, to avoid sudden failure and to improve overall picture quality. The lamplife remaining can be checked using the OSD menu. 1 Press Menu. - The menu bar appears on the screen. 2 Use Cursor Control to move the cursor to 'Settings'. 3 Use Cursor Control to select 'Lamp counter'. - The remaining lamplife hours are displayed in the action window at the bottom of the screen. - When the lamplife has expired, the lamp indicator lights up red and the message 'Warning: lamplife has expired' is displayed on the screen. Lamp Replacement 1 Switch off the projector and wait until the lamp has cooled down (about 5 minutes) before disconnecting the projector. Remove the mains lead from both projector and wall socket. AV Mute Source Menu OK The mains lead must be disconnected from the projector otherwise the lamp door Stand by Lamp Temp cannot be removed. 2 Turn the projector over. Never place the projector on the side where the connections are located! 3 Push tab A to the right and remove the lamp door. - When tab A is pressed the mains inlet socket will be partly closed. The lamp door therefore cannot be removed if the mains lead is not disconnected from the projector. 4 Read the caution and warning labels on the lamp holder. A Philips Multimedia Projector 29 English User guide bSure1 / bSure 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34

>
When operation time reaches the last 100 hours of the average lamplife, the message
Warning:
lamplife has almost expired
will be displayed on the screen, each time the projector is switched
on.The lamp indicator lights up orange.
The lamplife remaining can be checked using the OSD menu.
1
Press Menu.
The menu bar appears on the screen.
2
Use Cursor Control to move the cursor to
Settings
.
3
Use Cursor Control to select
Lamp counter
.
The remaining lamplife hours are displayed in the action window at the bottom of the
screen.
When the lamplife has expired, the lamp indicator lights up red and the message
Warning: lamplife has expired
is displayed on the screen.
1
Switch off the projector and wait until the lamp has cooled down (about 5 minutes) before
disconnecting the projector. Remove the mains lead from both projector and wall socket.
The mains lead must be disconnected from the projector otherwise the lamp door
cannot be removed.
2
Turn the projector over.
Never place the projector on the side where the connections are
located!
3
Push tab A to the right and remove the lamp door.
When tab A is pressed the mains inlet socket will be partly closed.
The lamp door therefore
cannot be removed if the mains lead is not disconnected from the projector.
4
Read the caution and warning labels on the lamp holder.
Lamp
Lamp Replacement
Philips Multimedia Projector
29
English
User guide
bSure1 / bSure 2
6. Maintenance
Warning:±
±
Lamplife has expired±
±
It is suggested to change the lamp, to avoid sudden ±
failure and to improve overall picture quality.
Picture
Audio
Settings
Display±
±
(previous)±
Start-up screen±
Lamp counter±
Auto standby±
Auto source±
Feedback±
±
±
Lamp±
5 Hours±
±
Lamp counter shows the operating hours of the ±
lamp. It is suggested to reset when a new lamp is ±
inserted. To reset keep OK key pressed ±
for 3 seconds.
Warning:±
±
Lamplife has almost expired±
±
It is suggested to have a spare lamp available. ±
The lamp type is indicated in the user guide.
Menu
OK
AV
Mute
Source
Stand
by
Lamp
Temp
Menu
OK
AV
Mute
Source
Stand
by
Lamp
Temp
Menu
OK
AV
Mute
Source
Stand
by
Lamp
Temp
Menu
OK
AV
Mute
Source
Stand
by
Lamp
Temp
A